Download Print this page
Whirlpool WGD6600W Dimensions And Installation Information
Whirlpool WGD6600W Dimensions And Installation Information

Whirlpool WGD6600W Dimensions And Installation Information

Gas dryer

Advertisement

Quick Links

Gas Dryer

®
PRODUCT MODEL NUMBERS
WGD6600V, WGD6600W
Gas supply:
Electrical:
Exhaust venting:
EXHAUST VENTING
Box hood style
4"
(102 mm)
4"
(102 mm)
Louvered style
Box or
Number of
Type of
o
90 turns
vent
Louvered
or elbows
hoods
0
64 ft (20 m)
Rigid metal
1
Rigid metal
54 ft (16.5 m)
2
Rigid metal
44 ft (13.4 m)
3
Rigid metal
35 ft (10.7 m)
Rigid metal
4
27 ft (8.2 m)
OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
4"
(102 mm)
2
1
/
"
2
(64 mm)
Angled style
Angled
hoods
58 ft (17.7 m)
48 ft (14.6 m)
38 ft (11.6 m)
29 ft (8.8 m)
21 ft (6.4 m)
43
1
/
"
2
(1105 mm)
29
1
/
"
4
(743 mm)
18"*
(457 mm)
1"
29"
(25 mm)
(737 mm)
A
IMPORT NT:
22
1
/
"
4
(565 mm)
29"
(737 mm)
14" max.*
(356 mm)
48"
2
*
2
(310 cm
)
2
24"
*
(155 cm
2
)
1"
5"
1
29
/
"
(25 mm)
4
(127 mm)
(743 mm)
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
3"*
(76 mm)
3"*
(76 mm)
C

Advertisement

loading

This manual is also suitable for:

Wgd6600wlWgd6600v