Connections Submenu - Bosch LTC-0498-28W Installation Manual

Hide thumbs Also See for LTC-0498-28W:
Table of Contents

Advertisement

38
en | Configuration
Item
Alarm output
EXIT
5.6.5

Connections submenu

Item
Sync. input
Notch filter
Bilinx Comms.
Camera
buttons
Cable
compensation
AR18-08-B013 | v1.0 | 2009.03
Selection
VMD,
External
device,
Night mode
active,
Filter toggle
Selection
High Z,
75 ohm
On, Off
On, Off
Enable,
disable
Off, Default,
RG59, RG6,
Coax12
Installation Manual
Description
VMD: - output relay closes on VMD alarms.
External device: - make the output relay
available to remote communication devices.
Night mode active: - output relay closes when
camera is in monochrome mode.
Filter toggle: - output relay closes just before
the IR filter starts moving and opens when
video level has stabilized (2 to 3 seconds)
Returns to Install menu.
Description
Select 75 ohm if the external sync input is not
terminated elsewhere.
Switches notch filter on or off. The notch
filter can remove a Moiré pattern or color
artifacts caused by closely spaced vertical
lines or objects (e.g. vertical security bars
over windows).
If Off, Bilinx communications is disabled.
Enable or disable the camera buttons from
working.
Cable compensation is used to avoid the
need for amplifiers in long distance coaxial
connections up to 1000 m (3000 ft). For
optimum results select the coaxial cable type
used or, if unknown, select default.
Dinion2X
Bosch Security Systems

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltc-0498-75wLtc-0630-61Dinion2xLtc0498Ltc 0630 series

Table of Contents