At command completion (I-O registers setting contents)
1F7
(ST)
H
1F6
(DH)
H
1F5
(CH)
H
1F4
(CL)
H
1F3
(SN)
H
1F2
(SC)
H
1F1
(ER)
H
The attribute value information is 512-byte data; the format of this data is shown
the following Table 5.8. The host can access this data using the SMART READ
DATA subcommand (FR register = D0h). The insurance failure threshold value
data is 512-byte data; the format of this data is shown the following Table 5.9.
The host can access this data using the SMART READ DATA subcommand
(FR register = D1h).
C141-E195-02EN
Status information
x
x
x
DV
Key-failure prediction status (C2h/2Ch)
Key-failure prediction status (4Fh/F4h)
xx
xx
Error information
5.3 Host Commands
xx