Troubleshooting; Diagnostics - NETGEAR GS724TPS - ProSafe - Gigabit Stackable PoE Smart Switch Software Administration Manual

Gigabit stackable poe smart switch
Hide thumbs Also See for GS724TPS - ProSafe - Gigabit Stackable PoE Smart Switch:
Table of Contents

Advertisement

GS700TPS Smart Switch Software Administration Manual
After Reset – Select the image file that is active after the specific unit is reset. The
possible field values are:
Image 1 – Activates Image file 1 after the device is reset.
Image 2 – Activates Image file 2 after the device is reset.
2. Select the unit entry.
3. Select the image file to be active in the After Reset provided field in the first row.
4. Click APPLY to update the device. You must reset the device for the active image setting to
take effect. See
"Reset"

Troubleshooting

The Troubleshooting menu contains the following option:

"Diagnostics"

Diagnostics
The Diagnostics menu contains the following option:
"Cable Test"
Cable Test
The Cable Test screen contains fields for performing tests on copper cables. Cable testing provides
information about where errors occurred in the cable, the last time a cable test was performed, and
the type of cable error that occurred. The tests use Time Domain Reflectometry (TDR) technology
to test the quality and characteristics of a copper cable attached to a port. Cables up to 120 meters
long can be tested. Cables are tested when the ports are in the down state, with the exception of the
Approximated Cable Length test.