Hood Sensor

If the access panel is removed while there is still power to the computer, the hood sensor will cause the
system to stop and display the Error 912 message after system reboot and will beep 5 times for 5
seconds. If the alarm sounds, close the access panel, tighten the thumbscrew, then reboot the system.
The system will enter the operating system successfully. If the error message persists, press the
F10
key immediately when the HP Logo screen is displayed to enter the Computer Setup menu. In the menu,
select Advanced > Hood Sensor > Reset Case Open Status and make sure Enable is selected, then
press the
F10
key to Save and Exit, then reboot the system.
Installing a Security Lock