Eagle Cuda 240i S/GPS
Your sonar/GPS unit, the Cuda 240i, functions exactly like the Cuda
240 described in the manual provided (part 988-0152-012). In addition,
the Cuda 240i contains a communications port for NMEA 0183 output.
The instructions for connecting data cables and setting up the
communications port appear in this addendum.
NMEA 0183 Data Cable Connections
NMEA is a standard communications format for marine electronic
equipment. The Cuda 240i can send information to any device that
receives NMEA 0183 data. This allows the unit to work with VHF
marine radios equipped with the Digital Selective Calling (DSC)
distress call feature.
To send NMEA 0183 data, the Cuda 240i has one NMEA 0183 version
2.0 communication port. The com port can be used to send NMEA
formatted data such as your current position.
The provided Cuda 240i data cable plugs into the accessory socket on the
right side of the back of your unit's case. The data cable ends in two wires
that connect to your VHF radio or other NMEA device. The Cuda 240i uses
the yellow wire to transmit and the black shield wire for signal ground.
NOTE:
Some VHF radios, such as the popular Uniden
levels which require use of an additional diode and resistor built into
the Cuda 240i data cable. This is Wiring Diagram A, which is
described on page 2. The majority of the DSC radios will work with the
resistor and diode as provided by Eagle.
Addendum I
1
Pub. 988-0152-081
brand, have input

Advertisement

loading

Summary of Contents for Eagle CUDA 240I S

  • Page 1 Cuda 240i data cable. This is Wiring Diagram A, which is described on page 2. The majority of the DSC radios will work with the resistor and diode as provided by Eagle. Addendum I Pub. 988-0152-081 ...
  • Page 2 A few other radio brands (and other electronic devices) that meet the NMEA 0183 standard won't need these adapters and you will have to remove the resistor and diode to make those work. This is Wiring Diagram B, which is described on page 4. Consult your other device's owner’s manual, then read through all of the following instructions before you begin.
  • Page 3 Twist the exposed wires together as shown in the following figures. If you're using a Uniden or similar radio, connect the radio's NMEA Wire to the Cuda 240i data cable's yellow wire, and the radio's Ground/Shield wire to the Cuda 240i data cable's black shield wire. If you're using another radio brand or NMEA device, see Wiring Diagram B instructions at the end of page 3.
  • Page 4 After taping the wire ends individually, wrap the entire connection with electrical tape as shown. This will help protect from moisture and prevent the wires from breaking contact. Wiring Diagram "B" If your VHF radio or other device requires true RS-232, you will need to remove the diode and resistor built into the end of the Cuda 240i data cable.
  • Page 5 When the data cable is connected to your VHF radio, all you have to do is plug it into the sonar/GPS unit. Attach the data cable's plug to the accessory socket on the right side of the back of your unit's case.
  • Page 6: Communications Port Configuration

    Communications Port Configuration Now that you have the devices connected, use the Com Port command in the System Setup Menu to make them communicate. This command opens a menu that allows you to configure the communications port. Menus for changing Com Port settings. If you need additional assistance in configuring the unit to communicate with another device, consult the factory;...
  • Page 7: Configure Nmea

    To activate NMEA Output: From the Communication Ports menu, press ↓ to highlight NMEA Output. Press Output checkbox. To exit the Communication Ports menu, press Configure NMEA Once in the Communication Ports menu, you can configure the unit to use specific NMEA sentences. (The default setting has all NMEA sentences turned on.) Press ↓...
  • Page 8 As more marine electronics manufacturers enter this growing market, other connectivity issues with your unit may appear. You can check for known compatibility issues by visiting our web site, www.eaglesonar.com. Look in the Manuals section for updated documents for your sonar/GPS unit. This addendum supplements the manual Pub. 988-0152-081 Printed in USA 022704 to return to the previous page.