Toner Refresh
Purpose:
To clean the toner in each toner cartridge.
Values:
Yellow Crtrdg
Magenta Crtrdg
Cyan Crtrdg
Black Crtrdg
Drum Refresh
Purpose:
To clean the surface of the drum cartridge.
Initialize NVM
Purpose:
To initialize the non-volatile (NV) memory. After executing this function and rebooting the printer,
all the menu parameters are reset to their default values.
See Also:
"Resetting to Factory Defaults" on page 140.
Init Print Meter
Purpose:
To initialize the print meter of the printer. When the print meter is initialized, the meter count is reset
to zero.
Reset Fuser
Purpose:
To initialize the Machine Control Unit life counter.
Clear Storage
Note:
Clear Storage feature is available only when the 512 MB additional memory module is installed.
Cleans the toner in the yellow toner cartridge.
Cleans the toner in the magenta toner cartridge.
Cleans the toner in the cyan toner cartridge.
Cleans the toner in the black toner cartridge.