MAINTENANCE
DESCRIPTION
Entrapment Protection Devices
Warning Signs
Gate
Drive Chain (Slide Only)
The following should be checked by an authorized LiftMaster dealer:
DESCRIPTION
Manual Disconnect
Sprockets and Chains
Belt and Pulley (Slide
Only)
Accessories
Electrical
Chassis Mounting Bolts
Operator
Batteries
BATTERIES
Batteries will degrade over time depending on temperature and usage. For best performance, the batteries should
be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries. The operator comes with
two 7AH batteries. Two 33AH (A12330SGLPK) may be used in place of the 7AH batteries.
The batteries contain lead and need to be disposed of properly. Batteries do not perform well in extremely cold
temperatures.
NOTE: If your application includes a heater, two 33AH will not fit into the operator enclosure (swing only).
The operator alarm will beep 3 times with a command if the battery is low.
DRIVE CHAIN (SLIDE ONLY)
Over time, the drive chain on the operator will stretch and need to be tightened. To tighten the drive chain adjust
either of the two chain eye bolts.
NOTE: The chain should have no more than 1 inch of sag for every 10 feet of chain length.
CHECK AT LEAST ONCE EVERY MONTH
TASK
Check and test for proper operation
Make sure they are present
Inspect for wear or damage
Check for excessive slack and lubricate
TASK
Check and test for proper operation
Check for excessive slack and
lubricate
Check for excessive slack, wear, or
damage
Check all for proper operation
Inspect all wire connections
Check for tightness
Inspect for wear or damage
Replace
CHECK AT LEAST ONCE EVERY
6 MONTHS
3
3 YEARS
X
X
X
X
X
X
X
X