TIMER TO CLOSE

PROGRAM TIMER TO CLOSE BY EXAMPLE (Method 2):
To Program:
1. Close the door
2. Turn the selector dial to PROGRAM.
3. Press and hold TIMER button for 5 seconds until TIMER LED
flashes.
4. Press the OPEN button and wait for the door to reach full open or
mid stop position.
5. Wait for desired amount of time to pass. (An internal stop watch
starts counting when the door stops moving.)
6. Press the TIMER button or CLOSE button to stop the timer.
(TIMER SET LED will turn on.)
7. Turn the selector dial to the desired wiring type.
Example: The door should close 15 seconds after a truck enters a
garage. To program the Timer to Close, turn the selector dial to
PROGRAM, press the TIMER button until the TIMER LED blinks,
press the OPEN button and wait until the door reaches the open
position, wait for the truck to pass through, count 15 seconds and
then press the CLOSE button.
NOTES: To read back the Timer to Close setting, turn the selector
dial to Diagnostic and press the TIMER button. The OPEN LED will
flash once for every 5 seconds programmed and the CLOSE LED
will flash once for every 60 seconds programmed.
To deactivate the timer from the open position press the STOP
button. The timer will be reactivated on the next operation
command. To deactivate the timer for more than one cycle, attach a
switch to 11 & 12 (Common and Timer Defeat).
All timer modes require a supervised safety device to be installed.
Reminders: FSTS wiring mode allows the Timer to Close to be
activated by the Single Button Control (terminal 1) only. T wiring
mode allows the door to attempt to close only one time for safety
purposes.
A U T O M A T I C A L L Y L E A R N E D P R O G R A M M I N G
AUXILIARY REVERSAL SYSTEM / RPM SENSOR
Feature: This feature utilizes the RPM sensor connected to the
logic board to detect when the clutch slips and reverses the door
(clutch must be properly adjusted). In addition, the RPM
eliminates the need for a centrifugal switch on 1/3 and 1/2
horsepower single phase motors.
Benefit: The Auxiliary Reversal System reverses the operator
upon hitting an obstruction, preventing excessive door and
operator damage. We require the use of safety devices for
primary safety protection. By removing the centrifugal for 1/3 and
1/2 horsepower single phase motors, the leading cause of motor
failures is eliminated. (Auxiliary Reversal System not applicable
on models GH and GT.)
NOTE: This feature is automatically learned and does not require
programming.
P R O G R A M M I N G
LOSE
22
SELECTOR DIAL
Operation will vary
depending on
wiring type
OPEN
Logic Board
RPM Sensor