Alliance Laundry Systems 907003062 Installation Manual
Alliance Laundry Systems 907003062 Installation Manual

Alliance Laundry Systems 907003062 Installation Manual

120 pound capacity 170 pound capacity
Table of Contents

Advertisement

Quick Links

Tumble Dryers
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
120 Pound Capacity
170 Pound Capacity
Starting Serial No. 0907003062
Refer to Page 5 for Model Identification
www.comlaundry.com
TMB1268C
TMB1268
Part No. 70420801R8EN
November 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 907003062 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Alliance Laundry Systems 907003062

  • Page 1 Tumble Dryers Refer to Page 5 for Model Identification Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) 120 Pound Capacity 170 Pound Capacity Starting Serial No. 0907003062 www.comlaundry.com TMB1268C TMB1268 Part No. 70420801R8EN November 2011...
  • Page 3 These instructions must be posted in a prominent location. Step-by-step instructions of the above safety information must be posted in a prominent location near the tumble dryer for customer use. 70420801 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT WARNING W033...
  • Page 4  A "T-Handle" type gas shut-off valve must be installed in the gas supply line to this appliance.  This appliance must not be installed in a bedroom or bathroom. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT WARNING...
  • Page 5: Table Of Contents

    All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. 70420801 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Introduction... Model Identification ...
  • Page 6 Gas Burner Air Shutter ... 47 Airflow Switch... 48 Loading Door Strike ... 48 Loading Door Switch... 48 Belt Drive... 49 Removing Tumble Dryer from Service... 50 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN)
  • Page 7: Model Identification

    Alliance Laundry Systems at (920) 748-3950 for the name and address of the nearest authorized parts distributor. For technical assistance, call (920) 748-3121. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Introduction Steam/Thermal Oil...
  • Page 8: Serial Plate Location

    Inch 25.4 Inches W.C. 0.036 Inches W.C. 0.249 6.895 lb./inch (psi) 28.32 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 170 POUND Tumble Dryer Conversion Table To Obtain Multiply kCal Pounds/sq. inch Joules Pounds/sq. inch Millimeters Pounds (lbs.)
  • Page 9: Safety Information

    NOTE: The word “NOTE” is used to communicate installation, operation, maintenance or servicing information that is important but not hazard related. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Safety Information Failure to install, maintain, and/or operate this machine according to manufacturer’s...
  • Page 10: Important Safety Instructions

    12. Always clean the lint filter daily. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Save These Instructions 13. Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint, dust and dirt.
  • Page 11 27. Never operate the tumble dryer with any guards and/or panels removed. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) 28. DO NOT operate the tumble dryer if it is smoking, grinding, has missing or broken parts.
  • Page 12: Specifications And Dimensions

    Boiler Horsepower (Btu/hr.) (recommended operating pressure 80-100 psig) Heating Element Rating: Kilowatts (kW) N/A = Not Applicable © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 120 Pound 66 dBA 44 x 41 (1118 x 1041) (54.4)
  • Page 13: Pound Tumble Dryer Dimensions And Exhaust Outlet Locations

    Refer to Position and Level the Tumble Dryer to temporarily reduce the heights of these models. Models 63.45 in. 120L/N/E (1612 mm) 60.7 in. 120S (1542 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) TOP VIEW OF EXHAUST DUCT Cabinet Dimensions 48.91 in. 49.91 in.
  • Page 14: Pound Tumble Dryer Dimensions And Exhaust Outlet Locations

    Refer to Position and Level the Tumble Dryer to temporarily reduce the heights of these models. Models 42.38 in. 170L/N/S (1076 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT TOP VIEW OF EXHAUST DUCT Cabinet Dimensions 50.75 in.
  • Page 15: Electric And Gas Connection Locations For Gas Models

    18.34 in. 120L/N (466 mm) 21 in. 170L/N (533 mm) NOTE: These figures are approximate dimensions only. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) 77.84 in. 12.5 in. (1977 mm) (318 mm) 81 in.
  • Page 16: Electric And Steam Connection Locations For Steam Models

    170S Models 18.34 in. 120S (466 mm) 21 in. 170S (533 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Steam Inlet 35.875 in. (911 mm) 37.625 in. (956 mm) Steam Outlet 34.625 in. (879 mm) 44.625 in.
  • Page 17: Electric Connection Location For Electric Models

    Specifications and Dimensions Electric Connection Location for Electric Models TMB2336N Models 35.81 in. 85.64 in. 120E (910 mm) (2175 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN)
  • Page 18: Installation

    Due to varied requirements, applicable local codes should be thoroughly understood and all pre-installation work arranged for accordingly. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Installation Materials Required (Obtain locally) All Models...
  • Page 19 24 in. (610 mm) minimum, 36 in. (914 mm) recommended for maintenance purposes 0.25 in. (6 mm) recommended for removal or installation purposes, zero clearance allowed © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) IMPORTANT: Install tumble dryers with sufficient clearance for servicing and operation.
  • Page 20: Position And Level The Tumble Dryer

    7 seconds after the door is opened. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 7. Gas tumble dryers: Start the tumble dryer and check the burner flame. Adjust the gas inlet shutter as required.
  • Page 21: Required For Ce Models Only

    Refer to Removing Tumble Dryer from Service section. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Required for CE Models Only Once machine is installed, please be sure to complete the following items: ...
  • Page 22: Installing Ce Gas Drying Tumble Dryers

    © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Models are built in two different configurations:  Regulated Natural Gas – Injector is sized for Natural Gas, second family, group H (E) at 20 mbar inlet pressure.
  • Page 23 Burner orifice information at 0-2000 feet (0-600 meters) altitude. For Natural Gas, Group E+ applications, convert using L.P. Gas model and replace burner orifices. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Burner Supply...
  • Page 24: Basic Configuration

    (located ahead of the tumble dryer) that will maintain the gas supply at the inlet pressure specified. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT SPECIFIED LOCAL INLET PRESSURE...
  • Page 25: Specific Conversion Procedures

    How to Change Burner Orifice Size. 4. Commission tumble dryer for use. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) How to Change Burner Orifice Size 1. Disconnect electrical power from tumble dryer.
  • Page 26: How To Adjust Gas Valve Governor/Regulator

    Replace regulator cap. 5. Commission tumble dryer for use. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Pressure Tap Gas Valve Flange Gas Valve...
  • Page 27: Exhaust Requirements

    120 Pound 525 in. 170 Pound Table 3 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Make-up air openings with louvers will restrict air flow. The opening must be increased to compensate for area taken up by louvers.
  • Page 28 Discard Cover (Refer to step 4) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Alternate Venting for 120 Pound tumble dryers The 120 pound tumble dryer is equipped from the factory to exhaust from the top;...
  • Page 29: Individual Venting

    If 1200 feet per minute (366 meters per minute) cannot be maintained, schedule monthly inspections and cleaning of the ductwork. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Exhaust Requirements NOTE: The maximum length of a flexible metal duct must not exceed 7.87 ft.
  • Page 30 NOTE: Where exhaust duct pierces a combustible wall or ceiling, the opening must be sized per local codes. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT TMB2362N TMB2362N Figure 7 NOTE: Inside of duct must be smooth. Do not use sheet metal screws to join sections.
  • Page 31 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening MUST be sized per local codes. Duct Stations © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) ONE MANIFOLD ASSEMBLY Figure 8 120 Pound 10 in.
  • Page 32 NOTE: Where the exhaust duct pierces a combustible wall or ceiling, the opening MUST be sized per local codes. Duct Stations © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT TWO MANIFOLD ASSEMBLIES Figure 9 120 Pound 10 in. (254 mm) Duct 15 in.
  • Page 33: Gas Requirements

    New Zealand Obtain specific gas service pipe size from the gas supplier. Refer to Table 7 for general pipe size. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Gas Requirements The following must be furnished and installed by the customer for the gas service line to each tumble dryer.
  • Page 34 Use pipe compound, resistant to actions of L.P. Gas, on all pipe threads. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Check all pipe connections, internal and external, for gas leaks using a non- corrosive leak detection fluid.
  • Page 35: Gas Supply Pipe Sizing And Looping

    IMPORTANT: Gas loop piping must be installed as illustrated to equalize gas pressure for all tumble dryers connected to single gas service. Other gas using appliances should be connected upstream from loop. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) 25 ft. (7.6 m)
  • Page 36 3 (76.20) For L.P. Gas, correct the total Btu/hr. by multiplying it by 0.6. The answer is the equivalent Btu on the above chart. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Equivalent Length 50 feet 75 feet (15.25 m)
  • Page 37: High Altitude Orifice Sizing

    8001 – 10,000 2001 – 6000 L.P. 6001 – 10,000 * Btu/hr. derate of 4% per 1000 ft. (305 m) of altitude. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Non-CE Models inches 610 – 1220 0.1770...
  • Page 38: Electrical Requirements

    Code, Part I and/or local codes. Electrical work should be done by a qualified electrician. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT IMPORTANT: Electrical connections must be made by a qualified electrician using data on serial...
  • Page 39: For Ce Models Only

    NOTE: Activation of the emergency stop switch stops all machine control circuit functions, but DOES NOT remove all electrical power from machine. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) W070R1 W071 Electrical Requirements...
  • Page 40: Service/Ground Location

    Block Electrical Service Power Disconnect Models Through 7/31/11 Gas and Steam Terminal Block © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Ground and Terminal Block Locations Figure 12 (continued) Junction TMB2269N Ground Junction TMB2247N 70420801 (EN)
  • Page 41 Electrical Requirements Figure 12 (continued) Model Ground and Terminal Block Locations Terminal Electrical Ground Block Service Electric TMB2337N TMB2337N Contactor Figure 12 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN)
  • Page 42: To Connect Electrical Service To The Tumble Dryer

    – with selector switch in non-reverse position). If not, interchange leads L1 and L2 in the tumble dryer connection box. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN)
  • Page 43: Jumper Configuration Instructions

    380 Volt operation. Non-CE Models Ferrite Ring Junction Box © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Ferrite Ring Installation Models with RM Control Suffix Only The ferrite ring provided in the literature packet must be installed over the power leads during connection of electrical service.
  • Page 44: Electrical Requirements

    L1,L2,L3 and ground 460-480V/60Hz/3ph * Current ratings vary slightly depending on model; refer to serial plate. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT NOTE: Use copper conductors only. NOTE: 3 Phase Only– Each tumble dryer must be connected to its own individual branch circuit breaker, not fuses, to avoid the possibility of “single...
  • Page 45: Steam Requirements

     Install union and shut-off valve in return line and make final pipe connections to return header. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) NOTE: To prevent water hammering, route return lines below outlets of steam coils.
  • Page 46: Installing Steam Trap And Making Condensate Return Connections

    All components (solenoid valve, traps) must be supported to minimize loads on the tumble dryer steam coil connections. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Thermal Oil Prep It is the responsibility of the customer to install appropriate coil and heating system for thermal oil prep models.
  • Page 47: 120 Pound Tumble Dryers

    Vacuum Breaker (Optional) Steam Pressure Model 80-100 (5.3-6.9) 120S *Based on maximum psi. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) 18 in. (457 mm) Drop Solenoid Valve (Supplied with machine) Steam Bonnet Flexible Line...
  • Page 48: 170 Pound Tumble Dryers

    Condensate Return Line from Supply Line Steam Pressure Model 80-100 (5.3-6.9) 170S * Based on maximum psi. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Figure 15 Minimum PSI (bar) Supply Pipe Diameter 1-1/4 in. NPT...
  • Page 49: Adjustments

    3. To adjust the air shutter, loosen air inlet shutter adjusting screw. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) Adjustments 4. Open or close air shutter as necessary to obtain proper flame intensity.
  • Page 50: Airflow Switch

    To adjust, open door, loosen jam nut and turn door strike screw in or out as required. Retighten jam nut. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT W072R1 Door Strike Door Latch...
  • Page 51: En) © Copyright, Alliance Laundry Systems Llc – Do Not Copy Or Transmit

    4. Rotate the lower nut of the final drive eyebolt clockwise until proper belt tension is achieved. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN) 5. Rotate upper nut clockwise against the lower nut in order to lock it into place.
  • Page 52: Removing Tumble Dryer From Service

     Turn off manual gas shut-off valve on the machine.  Turn off steam supply external to machine.  Remove all electric, gas and steam connections. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70420801 (EN)