Remove Server Cover - All Servers; Attach Mounting Hardware - Some Servers; Hp Proliant Servers - HP DW017B - StorageWorks Ultrium 448 Tape Drive User Manual

Half-height sas tape drives
Hide thumbs Also See for DW017B - StorageWorks Ultrium 448 Tape Drive:
Table of Contents

Advertisement

Remove server cover - all servers

WARNING!
To avoid personal injury or damage to the server or tape drive, ensure that the server is disconnected
from the mains power supply while you install the drive.
CAUTION:
Static electricity can damage electronic components. Always wear an antistatic wriststrap if one is
available. If not, after you have disconnected power from the server and removed the cover, touch a bare
metal part of the chassis. Similarly, touch a bare metal part of the drive before installing it.
1.
Assemble the necessary tools and materials:
• Phillips screwdriver
• Flat-bladed screwdriver (if your server uses slotted screws)
• Torx screwdriver (if your server uses torx screws)
• Your server manuals (for reference during installation)
2.
Perform a normal system shutdown and turn off the server and any connected peripherals. Ensure
that the server is disconnected from the mains power supply.
3.
Remove the cover and front panel from the server, as detailed in your server's documentation.
As you work inside the server, you may have to disconnect other signal cables or power cords from
other devices to maneuver the new drive into place. If you have to do this, make a note of their
position and connections so you can put them back correctly later.
NOTE:
The server must provide forced cooling and be capable of drawing 6 cfm (0.17 m
or 10.08 m
reduces to 4 cfm at 35
blanking plates installed so that airflow is maintained.
4.
Remove the filler panel from a spare 5¼-inch bay of your server, as described in your server's
documentation. With some servers, such as the HP AlphaServer ES40, you must also remove the
half-height device divider.

Attach mounting hardware - some servers

If your server requires special rails or other hardware to install the tape drive, mount them on the tape
drive now.
If your server does not require special mounting hardware, proceed to
now.

HP ProLiant servers

NOTE:
If mounting hardware is supplied with your tape drive, it may not be exactly the same as shown in
the illustrations.
Different models of server require different mounting methods. The server may also incorporate a locking
mechanism to hold the tape drive in place. See
/hour) of air through the tape drive at up to 40
3
C ambient operation. Ensure that empty bays have the appropriate
0
C ambient operation. This
0
"Install drive - all
"Secure the drive - all
servers" on page 33.
Ultrium half-height SAS Tape Drives
/minute
3
servers" on page 25
23

Hide quick links:

Advertisement

Table of Contents