Table 2. Features and specifications
Microprocessor(s): Supports up to
two Intel Xeon dual-core, quad-core,
or hex-core microprocessors. For the
specific type and speed information
about the microprocessor, use
the Setup Utility program. See
"Using the Setup Utility program" on
page 109. For a list of the supported
microprocessors for your server, go to
http://www.lenovo.com/thinkserver.
On the ThinkServer systems page,
click Products ➙ Options ➙
ThinkServer Processors.
Memory modules:
• Minimum system memory: 2 GB
• Maximum system memory: 64 GB
(eight memory slots, each with one
8 GB RDIMM installed)
• Types: ECC, 1333 MHz, DDR3
registered SDRAM DIMMs only
• Slots: Eight dual inline memory
module (DIMM) slots
• Supports 2 GB, 4 GB, and 8 GB
RDIMMs
Integrated graphics card:
• 8 MB video memory
Size:
• Height: 43.6 mm (1.72 inches)
• Width: 436 mm (17.17 inches)
• Depth: 568 mm (22.36 inches)
• Maximum weight: 17 kg (37.48 lb)
when fully configured
RAID controllers:
• Onboard SATA Software RAID
• ThinkServer 8708ELP SAS RAID
Adapter
• ThinkServer 8708EM2 SAS RAID
Adapter
• ThinkServer RAID 700 Adapter
8
ThinkServer RD230 Hardware Maintenance Manual
Optical drive:
• Slim DVD/RW
Hard disk drive expansion bays
(depending on the model):
Up to four 3.5-inch SATA or SAS hard
disk drives
Expansion slots:
• Three PCI Express slots on the
system board and the PCI Express
x16 slot is for a riser card (there is
one PCI Express x16 slot on the
riser card)
Power supply: Single 600-watt
power supply
System fans: Five system fans
with automatic energy-saving noise
reduction technology
Integrated functions:
• Two single-port Gb Ethernet
controllers
• Six USB 2.0 connectors (two front
and four rear)
• Two RJ-45 Ethernet connectors
• One serial port
• One Video Graphics Array (VGA)
monitor connector
Electrical input
• Input voltage:
– Low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input frequency range: 50 to
60 Hz
– High range:
Minimum: 200 V ac
Maximum: 240 V ac
Input frequency range: 50 to
60 Hz
Environment:
• Air temperature:
– Server on: 10°C to 35°C (50°F
to 95°F); altitude: 0 to 914.4 m
(3 000 ft)
– Server on: 10°C to 32°C (50°F
to 89.6°F); altitude: 914.4 m (3
000 ft) to 2 133.6 m (7 000 ft)
– Server off: 10°C to 43°C (50°F
to 109.4°F); maximum altitude:
2 133.6 m (7 000 ft)
– Shipping: -40°C to 60°C (-104°F
to 140°F)
• Humidity:
– Server on: 8-90%,
non-condensing
– Server off: 8-90%,
non-condensing
– Shipping and storage: up to
93%, non-condensing
• Particulate contamination:
Attention: Airborne particulates
and reactive gases acting alone
or in combination with other
environmental factors such as
humidity or temperature might
pose a risk to the server.
Notes:
1. Power consumption and heat
output vary depending on the
number and type of optional
features installed and the
power-management optional
features in use.
2. The sound levels were measured
in controlled acoustical
environments according to
the procedures specified by the
American National Standards
Institute (ANSI) S12.10 and
ISO 7779 and are reported in
accordance with ISO 9296.
Actual sound-pressure levels in a
given location might exceed the
average values stated because
of room reflections and other
nearby noise sources. The
noise emission level stated
is the declared (upper limit)

Advertisement

Table of Contents