Brother BAS-311E Service Manual page 110

Programmable electronic pattern sewer with cylinder bed e series
Hide thumbs Also See for BAS-311E:
Table of Contents

Advertisement

Chapter 7
Error status
Probable causes
1. Conversion transformer improperly
wired (for 100 V, 110V specification)
To the power supply
To the power switch
(For 240 V, 380 V, 400 V, and 415 V
specifications)
To the power supply circuit board
To the power switch
(For 200 V, 220 V, and 230 V
#1 The
specifications)
power
No conversion transformer is
lamp does
installed.
not light
when the
2. Conversion transformer defective
power is
turned on.
3. Power supply cable defective
102
Note: Before adjustment, be sure to check that the
• Conversion in the control box
Check the transformer is correctly and securely wired
to the terminals.
(For 200 V, 220 V, and 230 V specifications, this is not
necessary.)
Separate P4 (ACIN) connectors on the power supply
circuit board, and check there is continuity between
pins 1 and 2 in the connector on the cable.
If there is no continuity, replace the conversion
transformer.
(For 200 V, 220 V, and 230 V specifications, this is not
necessary.)
Separate P4 (ACIN) connectors on the power supply
circuit board, turn on the power, and measure the
voltage across pins 1 and 2 in the connector on the
cable.
If the voltage is as shown in the table below, the
power supply cable is not defective.
After checking, turn off the power, and rejoin P4
ACV
connectors.
BAS-311E.311EL.326E.326EL
Check/repair/adjust
power is turned off to prevent electric shock.
If the power is turned on, turn off the power,
and wait at least 5 minutes.
The same as the
For 200 V, 220 V, and
power supply voltage
230 V specifications
of wall socket
For 100 V, 110 V, 240
V, 380 V, 400 V, and
415 V specifications
Parts to be replaced
Power supply cable
About 220 V
Conversion
transformer