Cr_Filrepl Command; Cr_Filtimer Command - Sanyo PDG-DWL2500 - 2500 Lumens Functional Specifications

Expand series command functional specifications
Hide thumbs Also See for PDG-DWL2500 - 2500 Lumens:
Table of Contents

Advertisement

PDG-DWL2500 Expand Serial Command Functional Specifications

9.11.29 CR_FILREPL Command

Command
"CR_FILREPL"[CR]
Details
Get the information of Filter replacement time
Acceptable
Response
Unacceptable

9.11.30 CR_FILTIMER Command

Command
"CR_FILTIMER" [CR]
Details
Get setting time which filter warning OSD is displayed
Acceptable
Response
Unacceptable
"000_%1"[CR]
"1Y" ------------------- Over filter replacement time
%1
"1N" ------------------ Within filter replacement time
"Error Code"[CR]
"000_%1"[CR]
"2000" -----------------2000 hours
"3000" -----------------3000 hours
%1
"4000" -----------------4000 hours
"OFF" ---------------- No OSD display
"Error Code"[CR]
68/72

Advertisement

Table of Contents
loading

Table of Contents