Selecting Typical Installation; Safety Notice; Positioning The Stove; Clearance To Combustibles - Drolet SIT 0.820.633 Instruction Manual

Drolet direct vent gas stove instruction manual
Table of Contents

Advertisement

ULTRA FLAME DIRECT VENT GAS STOVE

SELECTING TYPICAL INSTALLATION

Safety Notice

Improper installation may result in a house fire. Follow installation directions. Installation must be
done in accordance with local building codes or, in the absence of local codes, with current
CAN/CGA B 149 installation codes for gas appliances (Canada) and current National Fuel Gas
Code ANSI Z223.1 (USA).
A qualified installer must do installation.
This gas stove must be vented outside.
This gas stove, when installed with optional blower or hand held remote, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the national
electrical code, ANSI/FPA 70, or the Canadian Electrical code, CSA C22.1.

Positioning the Stove

Always locate the stove as near as possible to an outside wall. Keep horizontal run of vent pipe as short
as possible;
Provide adequate clearances around air openings into the combustion chamber. Provide adequate
accessibility clearances for servicing and proper operation.
The ULTRA FLAME may be installed in a bedroom provided that all required clearances are met and a
wall thermostat is installed.
Never install the stove in a hallway or near a staircase as it may block the way in case of a fire
A gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning
appliance.

Clearance to combustibles

Clearance between the stove and any combustible material must also be maintained while installing your
appliance.
CLEARANCE
Back (in)
Side (in))
Corner (in)
Top (in)
Front (in)
Pipe (in)
Floor
Direct Installation
Note 1 :Your stove has been successfully certified while installed on a wood floor. Do not install your stove on carpet. Choose instead
ceramic tile or wood floor.
Clearance between wall and the pipe is 1". Do not install the vent pipe in an enclosed area or through an
insulated wall without a radiation shield ( # E-5710)
1
14
4
36
12
1
Note 1
Combustible
Corner Installation
Basement or Floor Installation
6