Clearances; Installation Of The Unit - Drolet Nova 820 Installation And Operating Instructions Manual

Vented gas fireplace insert (4 log style)
Table of Contents

Advertisement

ELATION Fireplace Insert

CLEARANCES

Clearance distances between the insert and any combustible material must be maintained while
installing your appliance:
Clearance to NON combustible hearth is:
Clearance to combustible mantel:
Clearance to combustible side wall:
Minimum hearth extension:

INSTALLATION OF THE UNIT

Move the ELATION to the desired position. Mark the location for the gas inlet pipe and the
location where the vent is in relation to the fireplace flue. Remove the appliance.
Route a 3/8" minimum NPT iron pipe gas line to the desired location.
Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound.
NOTE: The valve includes two ¼" tappings for test gauge connection. You may need,
however, to install a 1/8" plugged tapping between the gas line and the connection point to the
insert, if it is required by local codes.
0
38" (965 mm)
10" (254 mm)
16" (406 mm)
11