Drolet Nova 820 Installation And Operating Instructions Manual page 12

Vented gas fireplace insert (4 log style)
Table of Contents

Advertisement

ELATION Fireplace Insert
If you wish to make a direct electrical connection to the blower without using the six-foot
cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location.
Remove the power cord and connect the 120V line as per the following procedure :
• Unscrew the speed control unit and pull a few inches away from the junction box
• Unscrew the two marr connectors attached to the cord (P) and the cord ground
• Remove the cord and route the supply line through the same holes
• Make the electrical connection with the same wires the cord was attached to
• Screw the ground wire to the junction box (G)
• Screw the speed control unit back in place
CONNECT THE POWER LINE TO THE SAME
WIRES THE CORD WAS CONNECTED TO (P)
If you prefer to use the six-foot cord supplied, just connect it to a 120V outlet.
• Move the ELATION to the desired position and shim the unit to a level position.
• Connect gas line to the insert at the right side using listed connectors
• Check the gas line piping for leaks. Use a soap and water solution.
WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS.
P
G
P
JUNCTION BOX
SPEED CONTROL
12