Installation Instructions; Venting Requirements - Kenmore 8472 - 3.4 cu. Ft. Compact Portable Electric Dryer Use And Care Manual

120-volt compact electric dryer
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
Tools needed
Gather the required tools and parts before starting installation.
Read and follow the safety instructions
provided with any tools
listed here.
Flat-blade screwdriver
Caulking gun and
Level
compound
(for installing
new exhaust vent)
Adjustable wrench
Tin snips (new vent
Vent clamps
installations)
Parts supplied
Remove parts package from the dryer drum. Check that all parts
listed are included.
1 - Cycle Control (timer)
2 - Cord brackets
knob
2 - Screws
1 - Push to Start button
A sturdy floor to support the dryer weight (dryer and load) of
115 Ibs (52 kg). The combined weight of a companion
appliance should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer.
Do not operate your dryer at temperatures
below 45°F (7°C). At
lower temperatures,
the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation
Clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
4- Casters
Parts needed
Check local codes, existing electrical supply and venting, and
see "Venting Requirements"
and "Electrical Requirements"
before purchasing parts.
Mobile home installations require metal exhaust system
hardware
Permanent installations
require 4 dryer feet
The above are available for purchase from your local Sears store
or Sears Service Center. For further information, please call
1-800-4-MY-HOME
® (1-800-469-4663).
Expmosion Hazard
Keep flammabme materiams and vapors, such as
gasoline,
away from dryer.
PBace dryer at Beast 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can resumt in death, expmosion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A 120-volt, 60-Hz., AC-only, 15- or 20-amp circuit.
A grounded electrical outlet located within 2 ft (61 cm) of
either side of the dryer. See "Electrical Requirements."
?Height with caster is 327/2" (82.6 cm)
*Most installations require a minimum 51/2 '' (14.0 cm) clearance
behind the dryer for the exhaust vent with elbows. See "Venting
Requirements."
Minimum
installation
spacing for recessed area and closet
installation
The following dimensions shown are for the minimum spacing
allowed when the unit is to be operated with, or without, the
Stack Stand Kit. To purchase a Stack Stand Kit, please call
1-800-4-MY-HOME
® (1-800-469-4663).
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended
to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

110.84722

Table of Contents