Available languages
  • EN

Available languages

  • ENGLISH, page 22
_IA_CA1000.book Seite 31 Freitag, 30. Januar 2009 11:12 11
Dometic CA1000
7.3.1
Start and end configuration mode
The adjustable parameters can be altered in edit mode:
➤ With the system switched off, press the ON/OFF button (fig. e 1,
➤ With the system switched on, hold down the ON/OFF button for at
➤ Then hold down the Mode button (fig. e 4, page 6) for at least 2 sec-
➤ Let go of the ON/OFF button.
✓ The Compressor LED (fig. e 3, page 6) flashes.
➤ Let go of the Mode button.
✓ You are now in configuration mode.
✓ The first digit of the display (fig. e 5, page 6) shows the menu level
Note
I
If you make no entry on the control panel for 60 seconds, the system quits
configuration mode.
➤ Press the ON/OFF button to quit configuration mode.
7.3.2
Menu level 1: Set temperature
The system always starts with a defined value for the room temperature.
This parameter can be configured between 17 and 30 °C:
➤ Start configuration mode (see chapter "Start and end configuration
✓ The first digit of the display (fig. e 5, page 6) shows the menu level
➤ Press the Mode button (fig. e 4, page 6) to change the parameter.
➤ Use the + and – buttons (fig. e 6 und 7, page 6) to select the temper-
✓ The digits in the display flash until the parameter you enter is con-
➤ Press the Mode button (fig. e 4, page 6) to confirm your entry.
✓ The set value is saved and is then used when the system is restarted.
✓ You are now in menu level 1 and can use the + and - buttons to switch
page 6).
least 2 seconds.
onds.
and the second and third show the parameter which can be set – e.g.
for menu level 1 and a set value of 17 °C.
1.17
mode" on page 31).
and the second and third show the parameter which can be set.
ature (in °C) with which the system starts.
firmed.
between menu levels.
Installation
31

Hide quick links: