Wiring For Radio Receiver - ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating And Installation Instructions

Access control units
Hide thumbs Also See for ACTPRO 3000 ACCESS CONTROL UNITS:
Table of Contents

Advertisement

ON
1
2
3
4
ON
ON
1
2
3
4
1
2
3
4
+
-
+ DO D1 GND EN
24V GND 12V
+12V PSU

Wiring for Radio Receiver

Prastel MRRE Receiver
Use Belden 9502 or equivalent
Receiver may be maximum of
100metres from controller
Wiring Connections
0V
Receiver D1
Recevier D0
Not Connected
Recevier 0V
Not Connected
Not Connected
34 of 37
All Channels Enabled (Switches 1 to 4 ON)
Standard ISO Track 2:
Start Sentinel + 16 Digits + Seperator + End Sentinel + LRC
Link Sense to 0V
SENSE
CLOCK
DATA
5V
0V
RED
GREEN
Controller
SENSE
CLOCK
DATA
+5V
0V
RED
GREEN

Hide quick links: