Actwin Pro Configuration - ACT ACTPRO 3000 ACCESS CONTROL UNITS Operating And Installation Instructions

Access control units
Hide thumbs Also See for ACTPRO 3000 ACCESS CONTROL UNITS:
Table of Contents

Advertisement

NETWORK 1
NETWORK 2
A
B 0V
A
B 0V
ACTpro 3000
Click here to Connect
Select if Serial Port or
Modem or TCP/IP Connection
A
B
0V
CTS
From the Installer Menu, do the following:
DTR
1. Factory Default the controller.
RX
TX
0V
2. Go to the Communications menu and Set Address. If there is only 1
controller, set the address to 1. For more than 1, assign each controller
a unique address, starting at 1.
GREEN
RED
3. Set Direct Connect to Yes if the PC is connected directly to one controller (as
shown above). Set to No if it is a networked system. For more than one
controller, an RS-485 Network Interface is required.
4. Connect the controller(s) to the PC.
5. From ACTWin pro, configure a new database.
6. Follow the database creation wizard.
7. Ensure that Comms is set up correctly.
8. Connect to the controllers.
Page 29
Direct Connect Cable
ACTWin pro
Click here to configure Comms
Select if Direct Connect or
Networked
Select COM port and Speed