IBM 8676 - Eserver xSeries 335 Installation Manual page 59

Installation guide
Hide thumbs Also See for 8676 - Eserver xSeries 335:
Table of Contents

Advertisement

Symptom
Memory problems
The amount of system memory
displayed is less than the
amount of physical memory
installed.
Microprocessor problems
The server emits a continuous
tone during POST.
Monitor problems
Testing the monitor.
The screen is blank.
Only the cursor appears.
Suggested action
Verify that:
v The memory modules are seated properly.
v You have installed the correct type of memory.
v If you changed the memory, you updated the memory configuration with the
Configuration/Setup Utility program.
v All banks of memory on the DIMMs are enabled. The server might have
automatically disabled a DIMM bank when it detected a problem or a DIMM
bank could have been manually disabled.
Look in the POST error log for error message 289:
v If the DIMM was disabled by a system-management interrupt (SMI), replace the
DIMM.
v If the DIMM was disabled by the user or by POST:
1. Start the Configuration/Setup Utility program.
2. Enable the DIMM.
3. Save the configuration and restart the server.
v If you continue to get this error, replace the DIMM.
If the problem remains, call for service.
The startup (boot) microprocessor is not working properly.
Verify that the startup microprocessor is seated properly. If it is, replace the startup
microprocessor.
If the problem remains, call for service.
Some IBM monitors have their own self-tests. If you suspect a problem with your
monitor, see the information that comes with the monitor for adjusting and testing
instructions.
If you still cannot find the problem, call for service.
Verify that:
v The server power cord is plugged into the server and a working electrical outlet.
v The monitor cables are connected properly.
v The monitor is turned on and the Brightness and Contrast controls are adjusted
correctly.
If the servers are C2T chained together, verify that:
v The C2T chain cables are securely connected to the servers.
v The C2T breakout cable is connected properly.
v A server that is turned on is selected.
Important: In some memory configurations, the 3-3-3 beep code might sound
during POST followed by a blank monitor screen. If this occurs and the Boot Fail
Count feature in the Start Options of the Configuration/Setup Utility program is
enabled (its default setting), you must restart the server three times to force the
system BIOS to reset the settings in CMOS memory to the default configuration
(memory connector or bank of connectors enabled).
If you have verified these items and the screen remains blank, call for service.
Call for service.