Before connecting the switches in a power stack, keep in mind these guidelines:

StackPower Cabling Configurations

This section describes the recommended cabling configurations for a StackPower stack. There are two
types of StackPower cables. The cable in
3750-X switch in a power stack or to an XPS 2200. The cable in
or 3560-X switch to an XPS 2200.
Note
All cable connectors are keyed and color-coded, as are the connections on the switches (See
and
Both cable types are available in two lengths.
OL-19593-02
A switch power stack can include a maximum of four switches in a ring topology and nine switches
in a star topology with the XPS 2200.
Size of the switch and any optional power supply module. The 1100-W power-supply module is
1.5 inches longer than the other modules, and with the attached cable retention clip, it extends
3 inches from the switch chassis. Stacking switches with the same power-supply modules together
makes it easier to cable the switches. For switch dimensions, see
Specifications."
Length of cable. Depending on the configurations that you have, you might need different-sized
cables. If you do not specify the length of the StackPower cable, the 0.3 meter cable is supplied. If
you need the 1.5 meter cable, you can order it from your Cisco supplier. For cable part numbers, see
the
"StackPower Connector (Catalyst 3750-X Switches)" section on page
Cabling Configurations" section on page 2-9
For rack-mounted switch stacks that are members of a data stack and a StackPower stack, see the
"Switch Data Stacking Guidelines" section on page
For rack-mounted switch stacks connected to the XPS 2200, review this recommended sequence of
events:
If you are using the XPS 2200, first install the XPS at the bottom of the stack. If needed, allow
one RU space between the XPS and the first switch above to provide room for cabling.
Connect all the 12-pin XPS cables to the XPS 2200 as needed.
Rack-mount the switches. If you have the optional 1100-W power-supply module, first
rack-mount the switch before installing the power-supply module.
Connect the XPS cable to the first switch above the XPS 2200. Connect the stack cables to the
first switch above the XPS.
Connect the XPS cable to the second switch above the XPS 2200. Connect the stack cables to
the second switch above the XPS.
Repeat until all devices are connected.
Figure 1-8 on page
1-18).
provides examples of recommended configurations.
2-5.
Figure 2-8
connects a Catalyst 3750-X switch to another
Figure 2-9
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
StackPower Cabling Configurations
Appendix A, "Technical
1-22. The
"StackPower
connects a Catalyst 3750-X
Figure 1-7
2-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws-c3560x-48pf-sCatalyst 3750-xCatalyst 3560-x

Table of Contents