Sharp CV-2P10SX Installation And Operation Manual page 14

Portable type room air conditioner
Hide thumbs Also See for CV-2P10SX:
Table of Contents

Advertisement

Available languages

Available languages

INSTALL WINDOW PANEL
Installation in a sliding sash window
1
Connect the rain guards to the insect
guard net.
Insert all three projections on each rain
guard into the holes in the insect guard net.
Side "A" will now be at the top, as indicated
in the diagram.
2
Attach the guard combined above to
the window panel.
Push the insect guard net firmly to ensure
that its four projections fit into the holes in
the window panel.
Side "A" will now be at the top, as indicated
in the diagram, when it is installed in the
window.
3
Cut the foam seal A (adhesive type)
to the proper length and attach it to
the window frame.
4
Install the window panel into the win-
dow frame.
Make sure that the exhaust cover is
attached to the window panel.
Inner height of the window:
21.3" (540mm) - 28.3" (718mm)
Use the window panel.
The window panel cannot be installed in
windows less than 21.3" (540mm) high, as
you will be unable to shut the exhaust cover.
(1) Cut the window panel to the same height
as the window.
(2) Open the window sash and place the
window panel on the window frame.
(3) Secure the window panel to the window
frame with 2 screws.
CV-2P13SX_en.indd 12
Insect guard net
Hole
Projection
Projection
EN-12
"A"
Rain guard
Window panel
"A"
Foam seal A
Exhaust cover
Window panel
Cut
21.3" - 28.3"
11.3.3 5:58:17 PM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv-2p12sxCv-2p13sx

Table of Contents