About Out of Band Management Component pages
General page
Options on the General page (continued)
Table 2-15
Option
Use one time password
Requireconfirmationbefore
Intel AMT configuration
First Common Name (CN) in
certificate subject name
Queue polling period
Worker threads
Log level
Keep log for
Keep security audit log for
Description
Check to require a one-time password (OTP) exchange
between Intel SCS and the Intel AMT device that is
requesting setup and configuration. This feature adds more
security.
When the Intel SCS receives a Hello message from an Intel
AMT device, setup and configuration will proceed
automatically, unless this option is checked. If you check
this option, you must authorize setup and configuration
through the Authorize systems operation on the Intel AMT
Systems page.
See
"Intel AMT systems page"
Select an option that matches your root certification
authority certificate s CN field.
This parameter determines how frequently Intel SCS checks
the queue in the database for new tasks.
The default is 1000 milliseconds.
This parameter determines the maximum number of SCS
operations that can be performed concurrently by each SCS
service. The operations are: configuring or unconfiguring
an Intel AMT platform, synchronizing clocks, and so on.
This value can be adjusted to optimize the service s
performance, depending on the number of CPUs and the
memory size.
Default: 6 threads.
The system wide actions log can be recorded at several
levels. The more detail that is recorded, the more system
resources and bandwidth must be allocated.
This parameter determines how long log entries are saved.
The default is 10 days.
This parameter determines how long security status entries
are saved.
Default: 2 months.