4. Command Detail

Commands, data, and machine IDs which are described here are represented in characters (ASCII).
A command is a 2-byte character, a Machine ID is a 1-byte character, and each data is a 1-byte
character.
The DV-RA1000HD can have up to 99 tracks and up to 99 projects.

4-1. INFORMATION REQUEST

Requests the internal software version number of the controlled device.
Command
Data
Return
4-2. STOP
Puts the controlled device into STOP mode.
Command
Data
Return
4-3. PLAY
Puts the controlled device into PLAY mode.
Command
Data
Return
4-4. RECORD
Puts the controlled device into RECORD READY mode. When the controlled device is recording,
increments the track. Adds the track mark.
Command
Data
Return
Data 1
Data 2
0
1
0
2
・ If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
4-5. READY
Puts the controlled device into READY mode.
Command
Data
Return
Data 1
Data 2
0
1
・ If the specified data is other than described above, the controlled device sends ILLEGAL [F2].
0F
None
INFORMATION RETURN [8F]
10
None
None
12
None
None
13
2 bytes
None
Description
Remarks
Record Ready
Puts the controlled device into RECORD READY mode.
When the controlled device is recording, increments the track.
Track Mark
Adds the track mark.
14
2 bytes
None
Description
Remarks
Ready On
TASCAM DV-RA1000 RS-232C プロトコル仕様書
7