5-12. SINGLE PLAY RETURN
Transmitted in response to a SINGLE PLAY SENSE command [4E] with the request data ([FF]) to show
the currently set the Single Play status.
Command
Data
Request command SINGLE PLAY SENSE [4E]
Data 1
Data 2
0
0
0
1
5-13. MECHA STATUS RETURN
Transmitted in response to a MECHA STATUS SENSE command [50] and gives the current mechanism
status of the controlled device.
Command
Data
Request command MECHA STATUS SENSE [50]
Data 1
Drive
Data 2
Data 3
Status
Data 4
5-14. TRACK No. RETURN
Transmitted in response to a TRACK No. SENSE command [55], giving the current track status.
Command
Data
Request command TRACK No. SENSE [55]
Description
Data 1
Data 2
Data 3
Tens digit of the Track Number
Data 4
Units digit of the Track Number
Data 5
Thousands digit of the Track Number
Data 6
Hundreds digit of the Track Number
CE
2 bytes
Description
Single Play Off
Single Play On
D0
4 bytes
00: ODD
01: HDD
00: No Disc
01: Eject/Tray
02: CLOSE
10: Stop/Ready On
11: Play
80: OPC
81: Record
82: Record Ready
D5
6 bytes
TASCAM DV-RA1000 RS-232C プロトコル仕様書
Remarks
ODD mode
HDD mode
A disc is not loaded
When LCD shows "OPEN"
When LCD shows "CLOSE" or "DISC READING"
Transport is in Stop or Ready
Transport is in Play mode
In OPC processing
Transport is in Recording mode
Transport is in Record Ready mode
Remarks
Always 0
Always 0
20