Error Codes - HP Integrity rx1600 Deployment Manual

Smartsetup scripting toolkit deployment guide: hp integrity servers with linux
Hide thumbs Also See for Integrity rx1600:
Table of Contents

Advertisement

The error file displays the error code, error message, and if possible, lists the controller, array,
or logical drive associated with the error.
The format of the error file is as follows:
Line1:ACU Configuration Replication Error Line2:ERROR: (<error code>) <error description>
Line3:Controller: Slot # | SerialNumber # | WWN #
Line4:Array: #
Line5: Logical Drive: #
Table 6-8 Error Codes
Code
Error
0
Success
1
General error
2866
Failure opening capture file
'%s'
2867
Failure opening input file '%s'
2868
Failure opening error file '%s'
2869
'%s' command expected
2870
'%s' is not a supported command
2871
'%s' is not a Controller command
2872
'%s' is not an Array command
2873
'%s' is not a Logical Drive
command
2874
'%s' is not an HBA command
2875
More than one '%s' command
cannot exist in the same section
2821
No controllers detected
1102
Slot information is not
available
2819
Controller '%s' is invalid
2820
Could not detect Controller '%s'
2818
Invalid Method
2819
Invalid Controller
2822
Invalid Read Cache/Write Cache
Ratio
2823
Invalid Rebuild Priority
2824
Invalid Expand Priority
2857
Invalid Surface Scan Delay
Reason
Success
Problem spawning ACU process (user is not authenticated
to use ACU or ACU is already running).
Error opening capture file.
Error opening input file.
Error opening error file.
The specified command is missing or in the incorrect place
in the file.
The specified command is not a valid scripting command.
The specified command does not belong in the Controller
section of the script file.
The specified command does not belong in the Array section
of the script file.
The specified command does not belong in the LogicalDrive
section of the script file.
A command found in the HBA section is not a valid command
for this section.
The specified command is used more than once in the same
section. It should only be used once per section.
No controllers were detected. This error applies to input
mode only.
Input mode cannot be run on internal controllers without
slot information online. For Windows, this means the System
Management Driver has to be loaded.
The controller specified is not specified correctly.
The controller specified was not detected.
Invalid Method value.
Invalid Controller value.
The specified Read Cache/Write Cache Ratio is not supported
either by the controller or the current controller configuration.
The specified Rebuild Priority is not supported.
The specified Expand Priority is not supported. Also, this
error occurs if the controller does not allow expansion and
therefore does not support Expand Priority.
Invalid Surface Scan Delay
cpqacuxe
63