Power Supply Specifications - Compaq ProLiant 4500 Maintenance And Service Manual

Compaq proliant 4500r rack-mountable servers maintenance and service guide
Hide thumbs Also See for ProLiant 4500:
Table of Contents

Advertisement

Input Specifications
Nominal Line Voltage
Range Input Line
Frequency Range
Power Factor
Input Power
Input Current
Inrush Current
Holdup Time
General Specifications
Full Output Rating
Minimum Load
Ambient Temperature Range
Operating
Storage
Dielectric Voltage Withstand
Input to Output
Input to Ground
Safety Standard
EMI
Meets Requirements in:
Table 5-2

Power Supply Specifications

100 to 120 VAC
90 to 132 VAC
47 to 63 Hz
0.95
825
10.0 A at 120 VAC
80 A at 132 VAC (cold start) 80 A at 264 VAC (cold start)
20 ms from zero crossing at
120 VAC
To 35 C and 5,000 ft
To 32 C and 10,000 ft
(derate linearly)
3.0 A on + 5V output;
0.5 A on + 12V output
50 to 120 F
-16 to 128 F
3000 VAC/ minute
1500 VAC/ minute
UL 1950; CSA 22.2 #950 or CSA 22.2 #234;
TUV/VDE EN 60 950 (VDE0805/11.92); EMKO-TUE
(74-SEC) 207/94
CISPR Publication 22 Class B; BMPT - AmtsblVfg
243/1991 limits; CFR 47, Part 15 Class A limits.
IEC 801-2
IEC 801-3
IEC 801-4
EN50 082
Physical and Operating Specifications
200 to 240 VAC
180 to 255 VAC
47 to 63 Hz
0.95
900
5.0 A at 240 VAC
20 ms from zero crossing at
240 VAC
10 to 55 C
-30 to 60 C
Maintenance and Service Guide
5-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant 4500r

Table of Contents