Compaq ProLiant 4500 Maintenance And Service Manual page 50

Compaq proliant 4500r rack-mountable servers maintenance and service guide
Hide thumbs Also See for ProLiant 4500:
Table of Contents

Advertisement

3-18
Diagnostic Tools
Error
Code
600-xx
601-xx
602-xx
603-xx
604-xx
605-xx
606-xx
607-xx
608-xx
609-xx
610-xx
694-xx
697-xx
698-xx
699-xx
Error
Code
802-xx
824-xx
Maintenance and Service Guide
Diskette Drive Error Test Codes
Description
Diskette ID drive types test failed
Diskette format failed
Diskette read test failed
Diskette write/read/compute test failed
Diskette random seek test failed
Diskette ID media failed
Diskette speed test failed
Diskette wrap test failed
Diskette write protect test failed
Diskette reset controller test failed
Diskette change line test failed
Pin 34 is not cut on 360 KB diskette drive
Diskette type error
Diskette drive speed not within limits
Diskette drive/media ID error
Monochrome Video Board Test Error Codes
Description
Video memory test failed
Monochrome video text mode test failed
Table 3-7
Recommended Action
The following steps apply to error
codes 600-xx through 698-xx:
1. Replace the diskette and re-test.
2. Check and/or replace the diskette
power and signal cables
and re-test.
3. Replace the diskette drive
and re-test.
4. Replace the system board
and re-test.
The following steps apply to 699-xx
error codes:
1. Replace the media and re-test.
2. Run the Configuration utility
and re-test.
Table 3-8
Recommended Action
The following steps apply to error
codes 802-xx and 824-xx:
1. Replace monitor and re-test.
2. Replace the Advanced VGA
board and re-test.
3. Replace monochrome board
and re-test.
4. Replace the system board
and re-test.