3-12
Diagnostic Tools
POST Error Messages
Error Code
1796-Drive Array - Array
Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
1797-Drive Array - Array
Accelerator Read Error
Occurred.
Data in Array Accelerator
has been lost.
Array Accelerator is
disabled.
1798-Drive Array - Array
Accelerator Write Error
Occurred.
Array Accelerator is
disabled.
1799-Drive Array - Drive(s)
Disabled due to Array
Accelerator Data Loss.
Select "F1" to continue with
logical drives disabled.
Select "F2" to accept data
loss and to re-enable
logical drives.
(Run System Configuration
Utility = "F10" key)
(RESUME = "F1" KEY)
Maintenance and Service Guide
Continued
Beeps
Probable Source of
Problem
None
Array Accelerator is
defective or has been
removed.
None
Hard parity error
while reading data
from posted writes
memory.
None
Hard parity error
while writing data to
posted writes
memory.
None
Volume failed due to
loss of data in
posted-writes
memory.
2L,2S
Power is cycled.
Temperature too hot.
Processor fan not
installed or spinning.
None
A configuration error
occurred during
POST.
None
As indicated to
continue.
Action
1.
Check that the Array
Accelerator is
properly seated.
2.
Run the System
Configuration Utility
to re-configure the
Compaq IDA-2
without the Array
Accelerator.
Enable Array
Accelerator.
Enable Array
Accelerator.
Press F1 to continue with
logical drives disabled or
F2 to accept data loss
and re-enable logical
drive.
Check fans.
Press F10 to run System
Configuration Utility.
Press the F1 key.

Hide quick links: