3-4
Diagnostic Tools
POST Error Messages
Error Code
173- Slot ID
Mismatch
174-
Configuration/Slot
Mismatch Device
Not Found
175-
Configuration/Slot
Mismatch Device
Found
176-Slot with Not
Readable ID Yields
Valid ID
177-Configuration
Not Complete
178-Processor
Configuration Invalid
179-System
Revision Mismatch
201-Memory Error
203-Memory
Address Error
205-Cache Memory
Error
Option-Cache
Memory Error
206-Cache
Controller Error
Maintenance and Service Guide
Continued
Beeps
Probable Source of
Problem
None
Board replaced, but
configuration not
updated.
None
EISA or PCI board not
found.
None
EISA or PCI board
added, configuration not
updated.
None
EISA or PCI board in slot
that should contain an
ISA board.
None
Incomplete System
Configuration.
None
Processor type or step
does not match
configuration memory.
None
A board was installed
that has a different
revision date.
None
RAM failure.
None
RAM failure.
None
Cache memory error.
Option Cache Memory
Error.
None
Cache controller failure.
Action
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run Diagnostics.
Run Diagnostics.
Replace the processor
board in the slot
indicated.
Replace the option cache
board.
Run Diagnostics.
Continued