Complete the installation
Once you have verified the wall panel is working properly it is time to mount it into the 2-gang wall box. This wall
box should be installed in the wall using industry-standard practices, and CAT-5 cable should be running from the
Navigator to the box (maximum distance is 200 feet of CAT-5 cable).
1. Remove the ribbon cable from the wall panel and store the cable and the Programing Port board in a safe place.
You will need this if you choose to re-program the wall panel.
2. Plug the CAT-5 cable into either one of the RJ-45 connectors on the back of the wall panel.
3. Mount the wall panel on the front of the box using the mounting screws that came with the box.
4. Test the wall panel again and confirm that it is controlling the Navigator. You are ready!
Tips and Troubleshooting
Cables
If the wall panel is not functioning properly cables are the most likely cause. Verify that your CAT-5 cables are
properly terminated with RJ-45 connectors. Check the cable with another device to be sure.
Version number is flashing
If the seond line of the wall panel LCD flashes on and off with the version number,
this indicates a problem in the programming of the Navigator Wall Panel Remote
software. The most likely problem is the LINK settings. Verify that each of your
menus are linked to a device, inputs or outputs, and a channel number. Follow
the steps in the Programming the Wall Panel and Transferring the Settings
sections of this operating guide and test the wall panel again. The version
number should no longer be flashing.
Controlling multiple channels
If you would like your menus to control multiple channels, you can choose
multiple links using the LINK command in the Navigator Wall Panel Remote
software. For example, you may want to mute all output channels. The
example at right shows the Link Setup for linking all 8 outputs of a
NAV4802-RC or NAV8802-RC. In this case we chose "Mute" in the
Command menu.
Error Updating
You may see this message in the Navigator Wall Panel Remote software.
When you start to program the wall panel the power must be off on your
Navigator (remember, the wall panel gets its power from the Navigator). If the
power is on you will see the "Error Updating" message. Turn off your
Navigator and chose Program->Update again. You should see the screen
that asks you to choose your comm port - proceed as shown in the
Transferring the Settings section of this operating guide.
Customer Service
If you have any other questions regarding the NAVRC-100 Wall Panel please contact us at sabine@sabine.com or
call 800-626-7394.
S
: U
N
EVEN
SING
AVIGATOR
O
H
PTIONAL
ARDWARE AND
S
F
OFTWARE
EATURES
Navigator Wall Panel OpGuide 070831.pmd rr
35
Navigator2 Op Guide 071010 KJS.pmd

Advertisement

Table of Contents
loading

Table of Contents