PRODUCT DATA SHEET
Base Grille Water Filtration
System
Model T1 KB2/T1 RFKB2 Capacity
200 Gallons
(757 Liters) without
Filter Indicator
Light
(_
Tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine Taste and Odor, Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity, Asbestos,
Lindane, Tetrachloroethylene,
Endrin, Alachlor,
Chlorobenzene
and Ethylbenzene.
This system has been tested according to NSF/ANSI 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSl 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L _+10%
0.08 mg/L
**
2.0 mg/L
95.93
97.36
Particulate Class I*
85% reduction
3533333#/mL
At east 10,000 part c es/mL
22000 #/mL
11567 #/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L _+10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
1OTto 10_fibers/L tt
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts;
>99.95%
120,000/L
50,000/L min.
8/L _
1/L;
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure =
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational,
maintenance, and filter
60 psig (413.7 kPa).
replacement requirements be carried out for the product to
perform as advertised.
Model T1KB2: Change the water filter cartridge every
6 months. If the water flow to the water dispenser or ice maker
decreases noticeably before 6 months have passed, replace
the water filter cartridge more often.
Use replacement cartridge T1RFKB2, part #9030. In Canada,
use replacement cartridge T1RFKB2, part #9030B.
2006 suggested retail price of $44.99 U.S.A./S50.99 Canada.
Prices are subject to change without notice.
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions,
actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection
before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
Refer to the front cover
or "Accessories"
section
for the
Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
ftFibers greater than 10 um in length
_Based on the use of Cryptosporidium
parvum oocysts
_) NSF is a registered trademark
of NSF International.
23

Advertisement

Table of Contents
loading

Table of Contents