Product Data Sheet - Kenmore Elite Side by Side Refrigerator Use & Care Manual

Side by side refrigerator
Hide thumbs Also See for Elite Side by Side Refrigerator:
Table of Contents

Advertisement

Available languages

Available languages

PRODUCT DATA SHEET
Base Grille Water Filtration System
Model TIKB1/TIRFKB1
Capacity
100 Gallons
(379 Liters)
(_
I Tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of
Chlorine Taste and Odor, Particulate
Class I*; and against
NSF/ANSl
Standard
53 for the reduction
of
Lead, Mercury, Atrazine,
Benzene,
Toxaphene,
O-Dichlorobenzene,
Cysts, Turbidity,
Asbestos,
L ndane, Tetrach oroethy ene, Endr n, A ach or, Ch orobenzene,
Ethy benzene, TTHM
and MTBE.
This system
has been tested according
to NSF/ANSl
42/53 for the reduction
of the substances
listed below. The concentration
of the
indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water
leaving the system,
as specified
in NSF/ANSl
42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L _+10%
0.08 mg/L
2.0 mg/L
95.93
97.36
Particulate Class I*
85% reduction
3533333#/mL
At east 10,000 part c es/mL 22000 #/mL**
11567 #/mL
99.38
99.67
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.010 mg/L
150 ug/L
0.15 mg/L _+10%
1.0 ug/L
1 ug/L
99.33
99.33
Lead: @ pH 8.5
0.010 mg/L
157 ug/L
0.15 mg/L _+10%
2.0 ug/L
1.08 ug/L
98.72
99.31
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.53
96.53
Mercury: @ pH 8.5
0.002 mg/L
0.0057 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.5
96.5
Benzene
0.005 mg/L
15 ug/L
0.015 mg/L _+10%
0.5 ug/L
0.5 ug/L
96.67
96.67
O-Dichlorobenzene
0.6 mg/L
1750 ug/L
1.8 _+10%
1.0 ug/L
1.0 ug/L
99.94
99.94
Toxaphene
0.003 mg/L
15 ug/L
0.015 _+10%
1.0 ug/L
1.0 ug/L
93.33
93.33
Atrazine
0.003 mg/L
10 ug/L
0.009 mg/L _+10%
2 ug/L
2 ug/L
80.8
80.8
Asbestos
99%
101 MFL
107to 108fibers/L *t
0.17 MFL
0.17 MFL
99.83
99.83
Live Cysts*
>99.95%
120,000/L
50,000/L min.
8/12
l/L*
99.99
>99.99
Turbidity
0.5 NTU
11.4 NTU
11 _+1 NTU
0.41 NTU
0.24 NTU
96.4
97.89
Alachlor
0.002 mg/L
41.3 ug/L
0.04 _+10%
0.2 ug/L
0.2 ug/L
99.52
99.52
Endrin
0.002 mg/L
5.9 ug/L
0.006 _+10%
0.5 ug/L
0.3 ug/L
91.5
95.47
Ethylbenzene
0.7 mg/L
1867 ug/L
2.1 _+10%
0.70 ug/L
0.0588 ug/L
99.96
100
Lindane
0.002 mg/L
1.9 ug/L
0.002 _+10%
0.02 ug/L
0.02 ug/L
98.93
98.93
Chlorobenzene
0.6 mg/L
2.0 ug/L
2.0 _+10%
0.0005 ug/L
0.0005 ug/L
99.98
99.98
Tetrachloroethylene
0.005 mg/L
14.2 ug/L
0.015 _+10%
0.5 ug/L
0.5 ug/L
96.47
96.47
TTHM
0.080 mg/L
465 ug/L
0.45 _+20%
1.0 ug/L
0.5 ug/L
99.78
99.88
MTBE
0.005 mg/L
14 ug/L
0.015 _+20%
0.70 ug/L
0.52 ug/L
94.94
96.27
Test Parameters:
pH = 7.5 + 0.5 unless otherwise
noted.
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried
out for the product
to
perform
as advertised.
Model
T1KB1 : The filter monitor
system measures the amount of
water that passes through the filter and alerts you to replace the
filter.
Style
1 - When the filter indicator
reads 10%, order a new filter.
When the filter indicator
reads 0%, it is recommended
that you
replace the filter.
Style 2 - When the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow
to red, it is recommended
that you replace the filter.
Use replacement
cartridge
T1RFKB1,
part #9020. In Canada,
use
replacement
cartridge
T1RFKB1,
part #9020B.
2005 suggested
retail price of $39.99
U.S.A./S59.95
Canada.
Prices are subject to
change without
notice.
These contaminants
are not necessarily
in your water supply.
While testing
was performed
under standard
laboratory
conditions,
actual performance
may vary.
The product
is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
Systems
certified
for cyst reduction
may be used on
disinfected
waters
that may contain
filterable
cysts.
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tfFibers greater than 10 um in length
*Based on the use of Cryptosporidium
parvum oocysts
® NSF is a registered trademark of NSF International.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Refer to the front cover or "Accessories"
section
for the
Manufacturer's
name, address
and telephone
number.
Refer to the "Warranty"
section
for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min) @ 60 psi
26

Hide quick links:

Advertisement

Table of Contents
loading