Summary of Contents for Juniper ERX - RELEASE 11.1.X MODULE GUIDE 4-6-2010
Page 1
E Series Broadband Services Routers Module Guide Release 11.1.x Juniper Networks, Inc. 1194 North Mathilda Avenue Sunnyvale, California 94089 408-745-2000 www.juniper.net Published: 2010-04-06...
Page 2
ERX 11.1.x Module Guide This guide provides an overview and description of the line modules (LMs), switch route processor (SRP) modules, and I/O modules available for the following Juniper Networks E Series Broadband Services Routers: ERX14xx models, ERX7xx models, and the ERX310 router. Unless otherwise specified, all line modules pair with I/O modules to create a module combination.
Page 3
Table 1: ERX Module Combinations First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page Channelized OC3/STM1 cOC3/STM1 multimode cOCx/STMx cOC3 STM1 F0 2.2.0 MULTIMODE cOC3/STM1 single-mode intermediate cOCx/STMx cOC3 STM1 F0 2.2.0 reach SINGLE MODE cOC3/STM1 single-mode long reach cOCx/STMx cOC3 STM1 F0...
Page 4
ERX 11.1.x Module Guide Table 1: ERX Module Combinations (continued) First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page GE 1000Base-LH (256-MB memory) GE/FE GE I/O SFP 5.0.0 GE 1000Base-ZX (256-MB memory) GE/FE GE I/O SFP 5.0.0 GE multimode GE/FE...
Page 5
Table 1: ERX Module Combinations (continued) First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page IPSec Service IPSec Service IPSEC No I/O module 4.0.2 SERVICE OC3/STM1 ATM OC3/STM1 ATM multimode without OCx/STMx OC3-4 I/O 5.0.0, APS/MSP redundancy (256-MB memory) ATM or 5.3.0...
Page 6
ERX 11.1.x Module Guide Table 1: ERX Module Combinations (continued) First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page OC3/STM1 POS single-mode intermediate OCx/STMx 4XOC3 APS 5.1.2 reach with APS/MSP redundancy 5.2.0 SINGLE MODE (APS/MSP) OC3/STM1 POS single-mode long reach OCx/STMx OC3-4 I/O...
Page 7
Table 1: ERX Module Combinations (continued) First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page OC12/STM4 POS multimode with OCx/STMx OC12 STM4 2.0.0 APS/MSP redundancy MULTI MODE OC12/STM4 POS single-mode OCx/STMx OC12 STM4 2.0.0 intermediate reach without APS/MSP redundancy SINGLE MODE OC12/STM4 POS single-mode...
Page 8
ERX 11.1.x Module Guide Table 1: ERX Module Combinations (continued) First Line Module I/O Module JUNOSe Combination Name and Type Label Label Support Page SRP-SE10G (1-GB memory) SRP-SE10G SRP-SE I/O 5.3.0 T3 ATM (4 ports) OCx/STMx 4xDS3 ATM 4.1.0 (128 ATM or OCx/STMx /DS3-ATM...
Page 9
cOC3/STM1 Multimode Module Combination cOC3/STM1 Multimode Module Combination cOCx/STMx F0 Line module label cOC3 STM1 F0 I/O I/O module label MULTI MODE Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description OC3/STM1 channelized to DS3, DS1, E1, and DS0 Supports either E1 or T1 operation, but not E1 and T1 operation simultaneously EFA ASIC Type...
Page 10
ERX 11.1.x Module Guide Up to four SC full duplex connectors Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 11
cOC3/STM1 Single-Mode Intermediate Reach Module Combination cOC3/STM1 Single-Mode Intermediate Reach Module Combination cOCx/STMx F0 Line module label cOC3 STM1 F0 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description OC3/STM1 channelized to DS3, DS1, E1, and DS0 EFA ASIC...
Page 12
ERX 11.1.x Module Guide Up to four SC full duplex connectors Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 13
cOC3/STM1 Single-Mode Long Reach Module Combination cOC3/STM1 Single-Mode Long Reach Module Combination cOCx/STMx F0 Line module label cOC3 STM1 F0 I/O I/O module label LONG HAUL Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description OC3/STM1 channelized to DS3, DS1, E1, and DS0 EFA ASIC...
Page 14
ERX 11.1.x Module Guide Up to four SC full duplex connectors Cables and connectors Tx power: min: –5.0 dBm max: 0 dBm Center wavelength: 1310 nm Rx input power: min: –34 dBm max: –7 dBm Fiber type: 9-micron core Rated for 40 km (24.8 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 15
cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination cOC12/STM4 Multimode Without APS/MSP Redundancy Module Combination cOCx/STMx F0 Line module label cOC12 STM4 F0 I/O I/O module label MULTI MODE Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description OC12/STM4 channelized to DS3, DS1, E1, and DS0...
Page 16
ERX 11.1.x Module Guide SC full duplex connector Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 17
cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination cOC12/STM4 Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination cOCx/STMx F0 Line module label cOC12 STM4 F0 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description...
Page 18
ERX 11.1.x Module Guide SC full duplex connector Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 19
cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination cOC12/STM4 Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination cOCx/STMx F0 Line module label COC12 F0 APS I/O module label SINGLE MODE Number of I/O ports 1 active, 1 redundant First supported: 6.1.3 or later 6.1.x release, 7.0.2 or later 7.0.x release, 7.2.0 and Software release higher-numbered release 130 W...
Page 20
ERX 11.1.x Module Guide SC full duplex connector Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –7 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 21
cOC12/STM4 Single-Mode Long Reach Module Combination cOC12/STM4 Single-Mode Long Reach Module Combination cOCx/STMx F0 Line module label cOC12 STM4 I/O module label LONG HAUL 1 active, 1 redundant Number of I/O ports First supported: 2.2.0 Software release Final supported: Not applicable 130 W Description OC12/STM4 channelized to DS3, DS1, E1, and DS0...
Page 22
ERX 11.1.x Module Guide SC full duplex connector Cables and connectors Tx power: min: –5.0 dBm max: 0 dBm Center wavelength: 1310 nm Rx input power: min: –34 dBm max: –7 dBm Fiber type: 9-micron core Rated for 40 km (24.8 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 23
CT3/T3 12 Module Combination (12 Ports) CT3/T3 12 Module Combination (12 Ports) CT3/T3-F0 Line module label CT3/T3 12 I/O I/O module label Number of I/O ports First supported: 3.2.0 Software release Final supported: Not applicable 130 W Description Channelized and unchannelized T3 EFA ASIC Type DS3, DS1, DS0...
Page 24
ERX 11.1.x Module Guide E3 Frame Module Combination (12 Ports) COCX-F3 Line module label E3-12 I/O module label FRAME I/O Number of I/O ports First supported: 4.0.2 Software release Final supported: Not applicable 135 W Description Unchannelized E3 for Frame EFA ASIC Type Capability...
Page 25
FE-8 Module Combination (8 Ports) (256-MB Memory) FE-8 Module Combination (8 Ports) (256-MB Memory) GE/FE Line module label FE-8 I/O I/O module label Number of I/O ports First supported: 5.0.0 Software release Final supported: Not applicable The GE/FE line module must have a minimum of 256 MB of memory to be used with JUNOSe Release 5.3.0 or a higher-numbered release.
Page 26
ERX 11.1.x Module Guide FE-8 SFP Module Combination (8 Ports) (256-MB Memory) GE/FE Line module label FE-8 SFP I/O I/O module label Number of I/O ports First supported: 6.0.0 Software release Final supported: Not applicable 130 W Description Fast Ethernet The FE-8 SFP I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cable lengths.
Page 27
FE-8 SFP Module Combination (8 Ports) (256-MB Memory) LC full duplex Cables and connectors (multimode fiber) Tx power: –20 dBm minimum and –14 dBm maximum Center wavelength: 850 nm Rx input power: –31 dBm minimum and –14 dBm maximum Rated for 2 km (1.2 miles) over 62.5/125-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 28
ERX 11.1.x Module Guide GE 1000Base-SX Module Combination (1 Port) (256-MB Memory) GE/FE Line module label GE I/O SFP I/O module label 1 active, 1 redundant Number of I/O ports First supported: 5.0.0 Software release Final supported: Not applicable 130 W Description Gigabit Ethernet 256 MB of memory...
Page 29
GE 1000Base-SX Module Combination (1 Port) (256-MB Memory) LC full duplex Cables and connectors (SX) Tx power: min: –9.5 dBm max: –4 dBm Center wavelength: 850 nm Rx input power: min: –20 dBm max: –0 dBm Rated for 275 m (300 yards) over 62.5-micron core cable Rated for 550 m (601 yards) over 50-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 30
ERX 11.1.x Module Guide GE 1000Base-LH Module Combination (1 Port) (256-MB Memory) GE/FE Line module label GE I/O SFP I/O module label 1 active, 1 redundant Number of I/O ports First supported: 5.0.0 Software release Final supported: Not applicable 130 W Description Gigabit Ethernet 256 MB of memory...
Page 31
GE 1000Base-LH Module Combination (1 Port) (256-MB Memory) LC full duplex Cables and connectors (LX/LH) Tx power: min: –9.5 dBm max: –3 dBm Center wavelength: 1300 nm Rx input power: min: –20 dBm max: –3 dBm Rated for 10 km (6.2 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 32
ERX 11.1.x Module Guide GE 1000Base-ZX Module Combination (1 Port) (256-MB Memory) GE/FE Line module label GE I/O SFP I/O module label 1 active, 1 redundant Number of I/O ports First supported: 5.0.0 Software release Final supported: Not applicable 130 W Description Gigabit Ethernet 256 MB of memory...
Page 33
GE 1000Base-ZX Module Combination (1 Port) (256-MB Memory) LC full duplex Cables and connectors (ZX) Tx power: min: –2 dBm max: 3 dBm Center wavelength: 1550 nm Rx input power: min: –22 dBm max: –3 dBm Rated for 70 km (43.4 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 34
ERX 11.1.x Module Guide GE Multimode Module Combination (1 Port) GE/FE Line module label GE I/O I/O module label MULTI MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 130 W Description Gigabit Ethernet This module combination has been superseded by a newer assembly;...
Page 35
GE Multimode Module Combination (1 Port) See “Module LEDs” on page 133. LEDs See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide, Alarms, errors, and events Chapter 5, Configuring Ethernet Interfaces. GE Multimode Module Combination (1 Port)
Page 36
ERX 11.1.x Module Guide GE Single-Mode Module Combination (1 Port) GE/FE Line module label GE I/O I/O module label SINGLE MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 130 W Description Gigabit Ethernet This module combination has been superseded by a newer assembly;...
Page 37
GE Single-Mode Module Combination (1 Port) See “Module LEDs” on page 133. LEDs See Monitoring Ethernet Interfaces in JUNOSe Physical Layer Configuration Guide, Alarms, errors, and events Chapter 5, Configuring Ethernet Interfaces. GE Single-Mode Module Combination (1 Port)
Page 38
ERX 11.1.x Module Guide GE2 1000Base-SX Module Combination (2 Ports) GE-2 Line module label GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP I/O module label 2 active, 2 redundant Number of I/O ports First supported: 5.3.0 Software release Final supported: Not applicable 100 W...
Page 39
GE2 1000Base-SX Module Combination (2 Ports) LC full duplex Cables and connectors (SX) Tx power: min: –9.5 dBm max: –4 dBm Center wavelength: 850 nm Rx input power: min: –17 dBm max: –3 dBm Rated for 275 m (300 yards) over 62.5-micron core cable Rated for 550 m (601 yards) over 50-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 40
ERX 11.1.x Module Guide GE2 1000Base-LH Module Combination (2 Ports) GE-2 Line module label GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP I/O module label 2 active, 2 redundant Number of I/O ports First supported: 5.3.0 Software release Final supported: Not applicable 100 W...
Page 41
GE2 1000Base-LH Module Combination (2 Ports) LC full duplex Cables and connectors (LX/LH) Tx power: min: –9.5 dBm max: –3 dBm Center wavelength: 1300 nm Rx input power: min: –20 dBm max: –3 dBm Rated for 10 km (6.2 miles) over 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 42
ERX 11.1.x Module Guide GE2 1000Base-ZX Module Combination (2 Ports) GE-2 Line module label GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP I/O module label 2 active, 2 redundant Number of I/O ports First supported: 5.3.0 Software release Final supported: Not applicable 100 W...
Page 43
GE2 1000Base-ZX Module Combination (2 Ports) LC full duplex Cables and connectors Tx power: min: –3 dBm max: 2 dBm Center wavelength: 1550 nm Rx input power: min: –23 dBm max: –3 dBm Rated for 70 km (43.4 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 44
ERX 11.1.x Module Guide GE High Density (HDE) Module Combination (2 Ports) GE-HDE Line module label GE-2 SFP I/O or 2XGE APS I/O SFP or GE-2 APS I/O SFP I/O module label 2 active, 2 redundant Number of I/O ports First supported: 7.0.0 Software release Final supported: Not applicable...
Page 45
GE High Density (HDE) Module Combination (2 Ports) LC full duplex Cables and connectors (LX/LH) Tx power: min: –9.5 dBm max: –3 dBm Center wavelength: 1300 nm Rx input power: min: –20 dBm max: –3 dBm Rated for 10 km (6.2 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 46
ERX 11.1.x Module Guide GE High Density (HDE) Module Combination (8 Ports) GE-HDE Line module label GE-8 I/O I/O module label Number of I/O ports First supported: 7.0.0 Software release Final supported: Not applicable 100 W Description Gigabit Ethernet The I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cabling distances.
Page 47
GE High Density (HDE) Module Combination (8 Ports) LC full duplex Cables and connectors Tx power: min: –9.5 dBm max: –3 dBm Center wavelength: 1300 nm Rx input power: min: –20 dBm max: –3 dBm Rated for 10 km (6.2 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 48
ERX 11.1.x Module Guide IPSec Service Module Combination IPSEC SERVICE Line module label No I/O module I/O module label Not applicable Number of I/O ports First supported: 4.0.2 Software release Final supported: Not applicable 130 W Description IPSec Tunnel Service EFA ASIC Type IPSec tunnels...
Page 49
OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory) OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC3-4 I/O I/O module label MULTI MODE Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release Final supported: Not applicable 130 W...
Page 50
ERX 11.1.x Module Guide SC full duplex connector Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 51
OC3/STM1 ATM Multimode With APS/MSP Redundancy Module Combination OC3/STM1 ATM Multimode With APS/MSP Redundancy Module Combination OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label 4XOC3 I/O module label APS I/O MULTI MODE 4 active, 4 redundant Number of I/O ports First supported: 5.1.2, 5.2.0 (APS/MSP) Software release Final supported: Not applicable...
Page 52
ERX 11.1.x Module Guide LC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 53
OC3/STM1 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OC3/STM1 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC3-4 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release Final supported: Not applicable...
Page 54
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 55
OC3/STM1 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OC3/STM1 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label 4XOC3 I/O module label APS I/O SINGLE MODE 4 active, 4 redundant Number of I/O ports First supported: 5.1.2, 5.2.0 (APS/MSP) Software release...
Page 56
ERX 11.1.x Module Guide LC full duplex Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 57
OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OC3/STM1 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC3-4 I/O I/O module label LONG HAUL Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release Final supported: Not applicable...
Page 58
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –5.0 dBm max: 0 dBm Center wavelength: 1310 nm Rx input power: min: –34 dBm max: –7 dBm Rated for 40 km (24.8 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 59
OC3/STM1 GE/FE Module Combination OC3/STM1 GE/FE Module Combination OC3/STM1 GE/FE Line module label OC3-2 GE APS I/O I/O module label 3; one active and one redundant port per SFP Number of I/O ports Ports 0 and 1 ATM interfaces Port 2 GE interface Port redundancy is not supported.
Page 60
ERX 11.1.x Module Guide LC-style fiber-optic connectors Cables and connectors (ATM Tx power: min: –19.0 dBm max: –14dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9db or over 50-micron core cable with an optical loss of 7 db See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 61
OC3/STM1 GE/FE Module Combination LC full duplex Cables and connectors (GE single mode LX40) Tx power: min: –4.5 dBm max: –0 dBm Center wavelength: 1300 nm Rx input power: min: –35 dBm max: –22.5 dBm Rated for 40 km (28.85 miles) over 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 62
ERX 11.1.x Module Guide Table 10: Single-strand SFPs Pairing (continued) Fiber Type Nominal Wavelength (nm) Maximum Operating Range (kilometers) 9 microns TX 1550 / RX 1310 10 (6.2 miles), matching SFP must have the same operating range Pairs with TX 1310, RX 1550 9 microns TX 1310, RX 1490 10 (6.2 miles), matching SFP must have...
Page 63
OC3/STM1 POS Multimode Without APS/MSP Redundancy Module Combination OC3/STM1 POS Multimode Without APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC3-4 I/O I/O module label MULTI MODE Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W Description Unchannelized, concatenated OC3/STM1 for POS...
Page 64
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 65
OC3/STM1 POS Multimode With APS/MSP Redundancy Module Combination OC3/STM1 POS Multimode With APS/MSP Redundancy Module Combination OCx/STMx POS Line module label 4XOC3 I/O module label APS I/O MULTI MODE 4 active, 4 redundant Number of I/O ports First supported: 5.1.2, 5.2.0 (APS/MSP) Software release Final supported: Not applicable 120 W...
Page 66
ERX 11.1.x Module Guide LC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 67
OC3/STM1 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination OC3/STM1 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC3-4 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W Description...
Page 68
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC3/STM1 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination...
Page 69
OC3/STM1 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OC3/STM1 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OCx/STMx POS Line module label 4XOC3 I/O module label APS I/O SINGLE MODE 4 active, 4 redundant Number of I/O ports First supported: 5.1.2, 5.2.0 (APS/MSP) Software release Final supported: Not applicable...
Page 70
ERX 11.1.x Module Guide LC full duplex Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 71
OC3/STM1 POS Single-Mode Long Reach Module Combination OC3/STM1 POS Single-Mode Long Reach Module Combination OCx/STMx POS Line module label OC3-4 I/O I/O module label LONG HAUL Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W Description Unchannelized, concatenated OC3/STM1 for POS EFA ASIC...
Page 72
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC3/STM1 POS Single-Mode Long Reach Module Combination...
Page 73
OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory) OC12/STM4 ATM Multimode Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 I/O I/O module label MULTI MODE Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release Final supported: Not applicable...
Page 74
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 75
OC12/STM4 ATM Multimode With APS/MSP Redundancy Module Combination OC12/STM4 ATM Multimode With APS/MSP Redundancy Module Combination OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 APS I/O module label MULTI MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 (128 MB), 5.0.0 (256 MB) Software release Final supported: Not applicable...
Page 76
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 77
OC12/STM4 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OC12/STM4 ATM Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release...
Page 78
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 79
OC12/STM4 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OC12/STM4 ATM Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 APS I/O module label SINGLE MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 (128 MB), 5.0.0 (256 MB) Software release...
Page 80
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –15 dBm max: –8 dBm Center wavelength: 1310 nm Rx input power: min: –31 dBm max: –8 dBm Rated for 15 km (9.3 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 81
OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OC12/STM4 ATM Single-Mode Long Reach Without APS/MSP Redundancy Module Combination (256-MB Memory) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 I/O I/O module label LONG HAUL Number of I/O ports First supported: 5.0.0, 5.3.0 or a higher-numbered release Software release...
Page 82
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –5.0 dBm max: 0 dBm Center wavelength: 1310 nm Rx input power: min: –34 dBm max: –7 dBm Fiber type: 9-micron core Rated for 40 km (24.8 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 83
OC12/STM4 ATM Single-Mode Long Reach With APS/MSP Redundancy Module Combination OC12/STM4 ATM Single-Mode Long Reach With APS/MSP Redundancy Module Combination OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label OC12 STM4 APS I/O module label LONG HAUL 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 (128 MB), 5.0.0 (256 MB) Software release...
Page 84
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –5.0 dBm max: 0 dBm Center wavelength: 1310 nm Rx input power: min: –34 dBm max: –7 dBm Fiber type: 9-micron core Rated for 40 km (24.8 miles) of 9-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 85
OC12/STM4 POS Multimode Without APS/MSP Redundancy Module Combination OC12/STM4 POS Multimode Without APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 I/O I/O module label MULTI MODE Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W Description Unchannelized, concatenated OC12/STM4 for POS...
Page 86
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 87
OC12/STM4 POS Multimode With APS/MSP Redundancy Module Combination OC12/STM4 POS Multimode With APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 APS I/O module label MULTI MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W...
Page 88
ERX 11.1.x Module Guide SC full duplex Cables and connectors Tx power: min: –19 dBm max: –14 dBm Center wavelength: 1310 nm Rx input power: min: –30 dBm max: –14 dBm Rated for 2 km (1.2 miles) over 62.5-micron core cable with an optical loss of 0–9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information.
Page 89
OC12/STM4 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination OC12/STM4 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 I/O I/O module label SINGLE MODE Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W...
Page 90
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC12/STM4 POS Single-Mode Intermediate Reach Without APS/MSP Redundancy Module Combination...
Page 91
OC12/STM4 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OC12/STM4 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 APS I/O module label SINGLE MODE 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable...
Page 92
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC12/STM4 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination...
Page 93
OC12/STM4 POS Single-Mode Long Reach Without APS/MSP Redundancy Module Combination OC12/STM4 POS Single-Mode Long Reach Without APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 I/O I/O module label LONG HAUL Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable 120 W...
Page 94
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC12/STM4 POS Single-Mode Long Reach Without APS/MSP Redundancy Module Combination...
Page 95
OC12/STM4 POS Single-Mode Long Reach With APS/MSP Redundancy Module Combination OC12/STM4 POS Single-Mode Long Reach With APS/MSP Redundancy Module Combination OCx/STMx POS Line module label OC12 STM4 APS I/O module label LONG HAUL 1 active, 1 redundant Number of I/O ports First supported: 2.0.0 Software release Final supported: Not applicable...
Page 96
ERX 11.1.x Module Guide See “Module LEDs” on page 133. LEDs See Monitoring SONET/SDH Interfaces in JUNOSe Physical Layer Configuration Alarms, errors, and events Guide, Chapter 3, Configuring Unchannelized OCx/STMx Interfaces. OC12/STM4 POS Single-Mode Long Reach With APS/MSP Redundancy Module Combination...
Page 97
OC48/STM16 POS Single-Mode Short Reach Module Combination OC48/STM16 POS Single-Mode Short Reach Module Combination OC48 Line module label OC48 FRAME APS I/O module label Number of I/O ports First supported: 4.1.x Software release Final supported: Not applicable 120 W Description Unchannelized, concatenated OC48/STM16 for POS FFA ASIC Type...
Page 98
ERX 11.1.x Module Guide Service Module (SM) Module Combination SERVICE MODULE Line module label No I/O module I/O module label Not applicable Number of I/O ports First supported: 5.1.0 Software release Final supported: Not applicable 130 W Description Tunnel Service for IP tunnels, L2F tunnels, and LNS termination EFA ASIC Type IP tunnels...
Page 99
SRP-5G+ Module Combination (1-GB Memory) SRP-5G+ Module Combination (1-GB Memory) SRP-5G+ Line module label SRP I/O I/O module label Number of I/O ports First supported: 4.1.3 or later 4.1.x release, 5.0.4 or later 5.0.x release, 5.1.2 Software release or higher-numbered release, 5.2.0 Final supported: Not applicable 125 W Description...
Page 100
ERX 11.1.x Module Guide SRP-5G+ Module Combination (2-GB Memory) SRP-5G+ Line module label SRP I/O I/O module label Number of I/O ports First supported: 4.1.3 or later 4.1.x release, 5.0.4 or later 5.0.x release, 5.1.2 Software release or higher-numbered release, 5.2.0 Final supported: Not applicable 125 W Description...
Page 101
SRP-10G Module Combination (2-GB Memory) SRP-10G Module Combination (2-GB Memory) SRP-10G Line module label SRP I/O I/O module label Number of I/O ports First supported: 4.1.3 or later 4.1.x release, 5.0.4 or later 5.0.x release, 5.1.2 Software release or higher-numbered release, 5.2.0 Final supported: Not applicable 125 W Description...
Page 102
ERX 11.1.x Module Guide SRP-40G PLUS Module Combination (2-GB Memory) SRP-40G PLUS Line module label SRP I/O I/O module label Number of I/O ports First supported: 4.0.0 Software release Final supported: Not applicable 210 W Description Switch route processor (40 Gbps) Has a minimum of 2 GB of error checking and correction (ECC) memory with a 1-GB nonvolatile storage (NVS) card.
Page 103
SRP-SE10G Module Combination (1-GB Memory) SRP-SE10G Module Combination (1-GB Memory) SRP-SE10G Line module label SRP-SE I/O I/O module label Number of I/O ports First supported: 5.3.0 Software release Final supported: Not applicable 35 W Description Switch route processor for ERX310 router only (10 Gbps) Not applicable Type Ethernet (IEEE 802.3)
Page 104
ERX 11.1.x Module Guide T3 ATM Module Combination (4 Ports) OCx/STMx ATM or OCx/STMx /DS3-ATM Line module label 4xDS3 ATM I/O I/O module label Number of I/O ports First supported: 4.1.0 (128 MB), 5.0.0 (256 MB) Software release Final supported: Not applicable 130 W Description Can use either the 128-MB OCx/STMx ATM line module or the 256-MB OCx/STMx...
Page 105
T3 Frame Module Combination (12 Ports) T3 Frame Module Combination (12 Ports) COCX-F3 Line module label CT3/T3 12 I/O I/O module label Number of I/O ports First supported: 4.0.2 Software release Final supported: Not applicable 135 W Description Unchannelized T3 for Frame EFA ASIC Type Capability...
Juniper Networks. If you use a feature before it has been fully qualified, it is your responsibility to ensure that it operates correctly in your targeted configuration.
Page 107
ERX 11.1.x Module Guide Table 11: Channelized OCx/STMx Modules (continued) cOCx FO Line Module with cOCx FO Line Module with Protocol or Application cOC3/STM1 Modules cOC12/STM4 FO I/O Modules BGP/MPLS VPNs Bridged Ethernet Bridged IP Cisco HDLC DHCP external server DHCP local server Dynamic interfaces DVMRP and GRE support access side...
Page 108
Appendix A: Module Protocol Support Table 11: Channelized OCx/STMx Modules (continued) cOCx FO Line Module with cOCx FO Line Module with Protocol or Application cOC3/STM1 Modules cOC12/STM4 FO I/O Modules L2TP/IPSec LAC support access side LAC support peer side LNS support peer side Local loopback MDL (maintenance data link) Mobile IP home agent...
ERX 11.1.x Module Guide Table 11: Channelized OCx/STMx Modules (continued) cOCx FO Line Module with cOCx FO Line Module with Protocol or Application cOC3/STM1 Modules cOC12/STM4 FO I/O Modules VRRP Channelized T3 Modules Table 12: Channelized T3 Modules CT3/T3-F0 Line Modules with Protocol or Application CT3/T3 12 I/O Modules Accepts traffic destined for GRE tunnels or DVMRP (IP-in-IP) tunnels...
Page 110
Appendix A: Module Protocol Support Table 12: Channelized T3 Modules (continued) CT3/T3-F0 Line Modules with Protocol or Application CT3/T3 12 I/O Modules IEEE 802.3ah OAM link-fault management IP multicast IP reassembly for tunneled packets IPSec IPv6 IPv6 multicast IPv6 neighbor discovery IS-IS J-Flow Statistics L2TP/IPSec...
ERX 11.1.x Module Guide Table 12: Channelized T3 Modules (continued) CT3/T3-F0 Line Modules with Protocol or Application CT3/T3 12 I/O Modules Remote loopback Subscriber interfaces (static) Subscriber interfaces (dynamic) Transparent bridging Tunnel-server ports Unified ISSU VPLS (network interfaces) VPLS (virtual core interfaces) VRRP Ethernet Modules Table 13: Fast Ethernet Modules...
Page 112
Appendix A: Module Protocol Support Table 13: Fast Ethernet Modules (continued) Protocol or Application GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O Modules DVMRP and GRE support access side DVMRP and GRE support server side Dynamic interfaces Ethernet raw mode encapsulation in Martini layer 2 circuits F4 OAM and F5 OAM (ATM administration) FDL (facilities data link) Firewall...
Page 113
ERX 11.1.x Module Guide Table 13: Fast Ethernet Modules (continued) Protocol or Application GE/FE Line Module with FE-8 I/O and FE-8 SFP I/O Modules MPLS MPLS L2VPNs over the LAGs configured between customer edge (CE) and provider edge (PE) devices Multilink Frame Relay Multilink PPP Network Address Translation (NAT)
Page 114
Appendix A: Module Protocol Support Table 14: Gigabit Ethernet Modules GE-2 Line Module or GE-HDE Line Module with GE-2 SFP GE/FE Line Modules with GE I/O (formerly GE-2 APS I/O GE-HDE Line Module with Protocol or Application I/O Modules or 2XGE APS I/O) GE-8 I/O Modules Accepts traffic destined for GRE tunnels or DVMRP...
Page 115
ERX 11.1.x Module Guide Table 14: Gigabit Ethernet Modules (continued) GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly GE-2 APS I/O GE/FE Line Modules with GE GE-HDE Line Module with Protocol or Application I/O Modules or 2XGE APS I/O) GE-8 I/O Modules IEEE 802.3ad link aggregation IEEE 802.3ah OAM link-fault...
Page 116
Appendix A: Module Protocol Support Table 14: Gigabit Ethernet Modules (continued) GE-2 Line Module or GE-HDE Line Module with GE-2 SFP I/O (formerly GE-2 APS I/O GE/FE Line Modules with GE GE-HDE Line Module with Protocol or Application I/O Modules or 2XGE APS I/O) GE-8 I/O Modules Network Address Translation...
ERX 11.1.x Module Guide OCx/STMx GE/FE Modules Table 15: OCx/STMx GE/FE Modules OCx/STMx GE/FE Line OCx/STMx GE/FE Line Modules Modules with OC3-2 GE APS with OC3-2 GE APS I/O Modules I/O Modules Protocol or Application (OC3/STM1 ATM Interfaces) (Gigabit Ethernet Interfaces) Accepts traffic destined for GRE tunnels or DVMRP (IP-in-IP) tunnels APS/MSP...
Page 118
Appendix A: Module Protocol Support Table 15: OCx/STMx GE/FE Modules (continued) OCx/STMx GE/FE Line OCx/STMx GE/FE Line Modules Modules with OC3-2 GE APS with OC3-2 GE APS I/O Modules I/O Modules Protocol or Application (OC3/STM1 ATM Interfaces) (Gigabit Ethernet Interfaces) IP multicast IP reassembly for tunneled packets IPSec...
ERX 11.1.x Module Guide Table 15: OCx/STMx GE/FE Modules (continued) OCx/STMx GE/FE Line OCx/STMx GE/FE Line Modules Modules with OC3-2 GE APS with OC3-2 GE APS I/O Modules I/O Modules Protocol or Application (OC3/STM1 ATM Interfaces) (Gigabit Ethernet Interfaces) PPPoE Remote loopback Subscriber interfaces (static) Yes (over bridged Ethernet and...
Page 120
Appendix A: Module Protocol Support Table 16: OCx/STMx ATM Modules (continued) OCx/STMx ATM Line Modules OCx/STMx ATM Line Modules Protocol or Application with OC3-4 I/O Modules with OC12/STM4 I/O Modules Bridged IP Cisco HDLC DHCP external server DHCP local server DVMRP and GRE support access side DVMRP and GRE support server side Dynamic interfaces...
Page 121
ERX 11.1.x Module Guide Table 16: OCx/STMx ATM Modules (continued) OCx/STMx ATM Line Modules OCx/STMx ATM Line Modules Protocol or Application with OC3-4 I/O Modules with OC12/STM4 I/O Modules Local loopback MDL (maintenance data link) Mobile IP home agent MPLS Multilink Frame Relay Multilink PPP Yes (with fragmentation and...
Appendix A: Module Protocol Support OCx/STMx POS and OC48 Modules Table 17: OCx/STMx POS and OC48 Modules OCx/STMx POS Line OCx/STMx POS Line OC48 Line Module with Modules with OC3-4 I/O Modules with OC48 Frame APS I/O Protocol or Application Modules OC12/STM4 I/O Modules Module...
Page 123
ERX 11.1.x Module Guide Table 17: OCx/STMx POS and OC48 Modules (continued) OCx/STMx POS Line OCx/STMx POS Line OC48 Line Module with Modules with OC3-4 I/O Modules with OC48 Frame APS I/O Protocol or Application Modules OC12/STM4 I/O Modules Module IEEE 802.3ah OAM link-fault management IP multicast IP reassembly for tunneled packets...
Appendix A: Module Protocol Support Table 17: OCx/STMx POS and OC48 Modules (continued) OCx/STMx POS Line OCx/STMx POS Line OC48 Line Module with Modules with OC3-4 I/O Modules with OC48 Frame APS I/O Protocol or Application Modules OC12/STM4 I/O Modules Module PPPoE Remote loopback...
Page 125
ERX 11.1.x Module Guide Table 18: Service Modules (continued) Protocol or Application Service Line Module (SM) IPSec Service Line Module Cisco HDLC DHCP external server DHCP local server DVMRP and GRE support access side DVMRP and GRE support server side Yes (over dedicated tunnel server ports) Yes (over dedicated tunnel server ports;...
Page 126
Appendix A: Module Protocol Support Table 18: Service Modules (continued) Protocol or Application Service Line Module (SM) IPSec Service Line Module Local loopback MDL (maintenance data link) Mobile IP home agent MPLS No (over GRE only) No (over GRE only) Multilink Frame Relay Multilink PPP Yes (with fragmentation and reassembly;...
ERX 11.1.x Module Guide Unchannelized E3 Modules Table 19: Unchannelized E3 Modules COCX-F3 Line Modules with E3-12 FRAME Protocol or Application I/O Modules Accepts traffic destined for GRE tunnels or DVMRP (IP-in-IP) tunnels APS/MSP ATM (point-to-point) BERT BGP/MPLS VPNs Bridged Ethernet Bridged IP Cisco HDLC DHCP external server...
Page 128
Appendix A: Module Protocol Support Table 19: Unchannelized E3 Modules (continued) COCX-F3 Line Modules with E3-12 FRAME Protocol or Application I/O Modules IP reassembly for tunneled packets IPSec IPv6 IPv6 multicast IPv6 neighbor discovery IS-IS J-Flow Statistics L2TP/IPSec LAC support access side LAC support peer side LNS support peer side Local loopback...
ERX 11.1.x Module Guide Table 19: Unchannelized E3 Modules (continued) COCX-F3 Line Modules with E3-12 FRAME Protocol or Application I/O Modules Subscriber interfaces (static) Subscriber interfaces (dynamic) Transparent bridging Tunnel-server ports Unified ISSU VPLS (network interfaces) VPLS (virtual core interfaces) VRRP Unchannelized T3 Modules Table 20: Unchannelized T3 Modules...
Page 130
Appendix A: Module Protocol Support Table 20: Unchannelized T3 Modules (continued) OCx/STMx ATM Line CT3/T3-F0 Line Modules COCX-F3 Line Modules with Modules with 4xDS3 ATM with CT3/T3 12 I/O Protocol or Application CT3/T3 12 I/O Modules I/O Modules Modules DVMRP and GRE support access side DVMRP and GRE support access side...
Page 131
ERX 11.1.x Module Guide Table 20: Unchannelized T3 Modules (continued) OCx/STMx ATM Line CT3/T3-F0 Line Modules COCX-F3 Line Modules with Modules with 4xDS3 ATM with CT3/T3 12 I/O Protocol or Application CT3/T3 12 I/O Modules I/O Modules Modules MDL (maintenance data link) Mobile IP home agent MPLS Yes (over PPP and Cisco...
Page 132
Appendix B Module LEDs This appendix describes the LEDs found on ERX modules. Module LEDs can show you the current status of a module and alert you to a problem with the module or one of its ports. We recommend that you familiarize yourself with LED activity so that you can easily detect and correct a module-related problem with minimal or no system downtime.
Page 133
ERX 11.1.x Module Guide Table 21: LED Identification and Activity Descriptions (continued) Location LED Label LED Indicator LED Color OFF to ON ON to OFF REDUNDANT Redundancy Green See Redundancy Status later in this appendix. modules NOTE: The REDUNDANT LED on the cOCx/STMx, FE-8, GE/FE, HSSI, and X.21/V.35 line modules is nonfunctional.
Page 134
Appendix B: Module LEDs Table 21: LED Identification and Activity Descriptions (continued) Location LED Label LED Indicator LED Color OFF to ON ON to OFF X.21/V.35 ACTIVE Port status Green Port configured Port not configured line module LOOPBK Port status Yellow Port in local loopback or Port not in loopback...
Page 135
ERX 11.1.x Module Guide Figure 1: SRP Module LEDs NOTE: The primary SRP module illuminates the REDUNDANT LED only when the SRP module detects that there is a secondary or standby SRP module online. The standby SRP module monitors an activity signal from the primary SRP module to determine its state;...
Page 136
Appendix B: Module LEDs Figure 2: FE2 Module LEDs Figure 3: E3 and T3 Module LEDs Redundancy Status You can determine the redundancy state of line modules by examining the online and redundant status LEDs (ERX7xx/14xx models only). See Table 22 on page 138. Redundancy Status...
Page 137
ERX 11.1.x Module Guide NOTE: The REDUNDANT LED on the cOCx/STMx, FE-8, GE/FE, and HSSI modules is nonfunctional. Table 22: Redundancy Status of a Line Module ONLINE LED REDUNDANT LED State of the Line Module Module is booting or is an inactive primary line module. Module is active, but no standby module is available.
Page 138
Appendix C Module Name Cross-Reference Information Module Name Cross-Reference Information on page 139 Module Name Cross-Reference Information Use Table 23 on page 139 to find the label name, software display name, and model number of a module. Table 23: Module Naming Reference Label Name Software Display Name Model Number...
Page 139
ERX 11.1.x Module Guide Table 23: Module Naming Reference (continued) Label Name Software Display Name Model Number GE/FE GE/FE ERX-GEFE256M-MOD GE-HDE GE-HDE-8 ERX-HDE-MOD GE-HDE GE-HDE-8 ERX-GE-MOD OC3/STM1 GE/FE 2xOC3-ATM 1xGE I/O ERX-OCXGE-MOD Service Modules IPSEC SERVICE IPsec ERX-IPSECURE-MOD SERVICE MODULE SERVICE MODULE ERX-SERVICE-MOD I/O Modules...
Page 140
Appendix C: Module Name Cross-Reference Information Table 23: Module Naming Reference (continued) Label Name Software Display Name Model Number cOC3 STM1 F0 I/O SINGLE MODE COC3–4SM I/O COC3F0–SM-I/O FE-8 I/O SFP FE-8 SFP FX I/O ERX-8FXSFP-IOA FE-8 I/O FE-8 I/O FE-8–I/O OC3-2 GE APS I/O SFP OC3-2A GE...
Page 141
ERX 11.1.x Module Guide Module Name Cross-Reference Information...
Product Reclamation and Recycling Program on page 143 Product Reclamation and Recycling Program Juniper Networks is committed to environmentally responsible behavior. As part of this commitment, we continually work to comply with environmental standards such as the European Union’s Waste Electrical and Electronic Equipment (WEEE) Directive and Restriction of Hazardous Substances (RoHS) Directive.
Page 143
ERX 11.1.x Module Guide Products returned through our reclamation process are recycled, recovered, or disposed of in a responsible manner. Our packaging is designed to be recycled and should be handled in accordance with your local recycling policies. Product Reclamation and Recycling Program...
Page 145
Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.
Need help?
Do you have a question about the ERX - RELEASE 11.1.X MODULE GUIDE 4-6-2010 and is the answer not in the manual?
Questions and answers