OneTouch  ULTRAMINI Owner's Booklet
Hide thumbs Also See for ONETOUCH ULTRAMINI:

Advertisement

Just the Basics of Testing
Sólo lo básico para la realización de pruebas
Blood Glucose Monitoring System
Sistema de supervisión de glucosa en sangre
Owner's Booklet
Manual del propietario

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ONETOUCH ULTRAMINI and is the answer not in the manual?

Questions and answers

Summary of Contents for OneTouch ONETOUCH ULTRAMINI

  • Page 1 Blood Glucose Monitoring System Sistema de supervisión de glucosa en sangre Just the Basics of Testing Sólo lo básico para la realización de pruebas Owner’s Booklet Manual del propietario...
  • Page 2 OneTouch ® UltraMini ™ Blood Glucose Monitoring System Owner’s Booklet...
  • Page 3 This owner’s booklet will help you learn how to use your meter properly. Please read it carefully. If you need assistance, please contact LifeScan Customer Service at 1 800 227-8862 (available 24 hours a day, seven days a week). Please...
  • Page 4: Table Of Contents

    Table of contents Setting up your system..............pg. 2 Starting the test process................pg. 7 Getting a blood sample ..............pg. 10 Applying blood and reading results..........pg. 22 Reviewing past results..............pg. 27 Control solution testing..............pg. 28 Caring for your system..............pg. 33 Understanding error and other messages........pg. 37 Detailed information about your system........pg.
  • Page 5 Before you begin Before using this product to test your blood glucose, carefully read this booklet and the inserts that come with the OneTouch ® Ultra ® Test Strips and OneTouch ® Ultra ® Control Solution. Take note of warnings and cautions throughout this booklet, which are identified æ...
  • Page 6 If any items are missing from your kit, call LifeScan Customer Service at 1 800 227-8862.
  • Page 7: Setting Up Your System

    Setting up your system Getting to know your OneTouch ® UltraMini ™ Blood Glucose Meter and test strips mg/dL is the pre-set unit of measure Display FRONT Edge to apply sample Confirmation window Test port Up and down buttons Insert test strip Turns the meter on or off here to turn meter Select or change information...
  • Page 8 The display will turn on and the meter will briefly screen, there may be a problem perform system checks. Or, to change the time and with the meter. Call LifeScan date, start with the meter off, then press and Customer Service at 1 800 227-8862.
  • Page 9 æ WARNING: If your display shows mmol/L rather than mg/dL, contact LifeScan Customer Service at 1 800 227-8862. You cannot change the unit of measure. Use of the wrong unit of measure may cause you to misinterpret your blood glucose level, and may lead to incorrect treatment.
  • Page 10 to the hour and changes when you pass 12:00. When the correct hour appears on the display, wait five seconds. Your entry will be saved and you will move to the next setting. Check AM/PM. If not correct, continue to press ▲ or ▼ until the hour and “AM” or “PM”...
  • Page 11 Step 5 Set the month Press ▲ or ▼ to change the month. When you have the correct month on the display, wait five seconds to move to the next setting. The day will now start flashing. Step 6 Set the day Press ▲...
  • Page 12: Starting The Test Process

    ® Ultra ® Test Strips your testing supplies, contact your healthcare • Lancing device professional or LifeScan Customer Service at • Sterile lancets with protective disks 1 800 227-8862. Failure to test could delay treatment • OneTouch ® Ultra ®...
  • Page 13 æ CAUTION: The test strip vial contains drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation. Step 2 Insert a test strip to turn on the meter Start with the meter off. If you have turned the meter on to change settings or review past results, turn it off.
  • Page 14 Step 3 Match the code on the meter with the code on the test strip vial If the code on the meter does not match the code on the test strip vial, press ▲ or ▼ to match the code number on the test strip vial. The new code number will flash on the display for three seconds, and then stay constant for three seconds.
  • Page 15: Getting A Blood Sample

    Getting a blood sample Overview of the OneTouch ® Lancing Device Release button Cocking control Depth indicator OneTouch ™ Clear Cap* ® (for alternate site sampling) Protective disk Blue cap* (for fingertip sampling) OneTouch UltraSoft Sterile Lancet ® ® Lancet point *The blue cap and OneTouch ®...
  • Page 16 Choosing the right sampling site at the right time The OneTouch ® UltraMini ™ Meter allows you to sample blood from your fingertip, forearm or palm. Forearm and palm sampling is also referred to as “alternate site testing” (AST). At times, results obtained at the forearm or palm may be different from a fingertip measurement.
  • Page 17 æ CAUTION: Do not test on your forearm or palm when: • You think your blood glucose is rapidly falling, such as within two hours of exercise or a rapid-acting insulin injection or insulin pump bolus. Testing with a fingertip sample may identify hypoglycemia or an insulin reaction sooner than testing with a forearm or palm sample.
  • Page 18 Choose a different puncture site each time you test. Repeated punctures in the same spot may cause soreness and calluses. If bruising occurs at an alternate site or you have difficulty getting a sample, consider sampling from a fingertip instead. You may want to review the choice of sites with your healthcare professional.
  • Page 19 Step 2 Insert a sterile lancet into the OneTouch ® Lancing Device Insert the lancet into the holder and push in firmly. Twist the protective disk until it separates from the lancet and save the disk for later use. Do not twist the lancet. Step 3 Replace the blue cap by snapping it back on Step 4...
  • Page 20 NOTE: A shallower puncture may be less painful. Try a shallower setting first and increase the depth until you find the one deep enough to get a blood sample of at least one microliter ( actual size). Step 5 Cock the OneTouch ®...
  • Page 21 Step 7 Get a round drop of blood Gently squeeze and/or massage your fingertip until a round drop of blood of at least one microliter ( actual size) forms on your fingertip. If the blood smears or runs, do not use that sample. Wipe the area and gently squeeze another drop of blood or puncture a new site.
  • Page 22 Forearm sampling Choose a fleshy area of the forearm away from bone, visible veins and hair. Sometimes there is less blood flow to the forearm than to the fingertips. To help you get a large enough drop of blood, you may gently massage or apply warmth to the site to increase blood flow.
  • Page 23 The OneTouch ® ™ Clear Cap Blue cap is used for forearm and palm for fingertip sampling only. Replace the blue sampling cap with the OneTouch ® ™ only Clear Cap. Step 1 Remove the blue cap by snapping it off Step 2 Insert a sterile lancet into the OneTouch ®...
  • Page 24 Step 3 Install the OneTouch ® ™ Clear Cap on the OneTouch ® Lancing Device by snapping it on Step 4 Adjust the depth setting You may have to adjust the OneTouch ® Lancing Device to a deeper setting to get a large enough drop of blood from your forearm or palm.
  • Page 25 Step 6 Puncture your forearm or palm Firmly press and hold the lancing device against your forearm or palm for a few seconds. Wait until the skin surface under the OneTouch ® ™ Clear Cap changes color (as blood collects beneath the skin).
  • Page 26 NOTE: • You may need to wait a little longer to get a large enough drop of blood from the forearm or palm. Do not squeeze the site excessively. • If the sample drop of blood runs or spreads due to contact with hair or with a line in your palm, do not use that sample.
  • Page 27: Applying Blood And Reading Results

    Applying blood and reading results Once you have a blood sample and your meter shows the screen with the flashing blood drop icon , you are ready to obtain a blood glucose result. If your meter does not show the screen with the flashing blood drop icon , remove the unused test strip and re-start the test process.
  • Page 28 Step 2 Top edge Apply the sample Touch and hold the drop of blood to the narrow channel in the top edge of the test strip. Blood will be drawn into the strip. Keep holding the drop of blood to the top edge of the test strip until the confirmation window is full.
  • Page 29 See page 42. Discard the strip and re-start the test process. æ WARNING: If mg/dL does not appear with the test result, call LifeScan Customer Service at 1 800 227-8862. Use of the wrong unit of measure may cause you to misin- terpret your blood glucose level, and may lead to incorrect treatment.
  • Page 30 æ CAUTION: High glucose results If your test result is higher than 180 mg/dL, it may mean hyperglycemia (high blood glucose). If you are uncertain about this test result, consider re-testing. Your healthcare professional can work with you to determine what actions, if any, you should take if your results are higher than 180 mg/dL.
  • Page 31 After getting a result Once you have read your result, you may: • Review your meter memory by pressing ▼ to enter memory mode, see page 27, or • Turn the meter off by removing the test strip. Removing the used lancet Remove the lancing device cap by snapping it off.
  • Page 32: Reviewing Past Results

    Reviewing past results The meter stores a maximum of 50 blood glucose test results. When the meter memory is full, the oldest result is dropped as the newest is added. Results are stored automatically when you test, along with the time, date and unit of measure. You can review the results stored in the meter memory, starting with the most recent.
  • Page 33: Control Solution Testing

    Control solution testing OneTouch ® Ultra ® Control Solution contains a known amount of glucose and is used to check that the meter and the test strips are working properly. Do a control solution test: • to practice the test process instead of using blood, •...
  • Page 34 æ CAUTION: Do not swallow control solution; it is not for human consumption. Do not apply control solution to the skin or eyes as it may cause irritation. Performing a control solution test Start with the meter off. If you have turned the meter on to change settings or review past results, turn it off.
  • Page 35 Step 3 Match the code on the meter with the code on the test strip vial If the code on the meter does not match the code on the test strip vial, press ▲ or ▼ to match the code number on the test strip vial. The new code number will flash on the display for three seconds, and then stay constant for three seconds.
  • Page 36 If you decide not to do a control solution test, press ▲ again to remove CtL from the display. Step 5 Prepare and apply control solution Shake the control solution vial before each test. Remove the cap and squeeze the vial to discard the first drop. Then wipe the tip with a clean tissue or cloth.
  • Page 37 CAUTION: If you continue to get control solution results that fall outside the range printed on the test strip vial, do not use the meter, the test strips, or the control solution. Call LifeScan Customer Service at 1 800 227-8862.
  • Page 38: Caring For Your System

    Caring for your system Your OneTouch ® UltraMini ™ Blood Glucose Monitoring System does not need any special maintenance. Storing your system Store your meter, strips and control solution in your carrying case after each use. Store each item in a cool, dry place below 86°F, but do not refrigerate. Keep all items away from direct sunlight and heat.
  • Page 39 CAUTION: Do not use your test strips if your vial is damaged or left open to air. This could lead to error messages or tests that read higher than the actual value. Call LifeScan Customer Service at 1 800 227-8862 immediately if the test strip vial is damaged. Cleaning your meter To clean your meter, wipe the outside with a soft cloth dampened with water and mild detergent.
  • Page 40 Battery Your OneTouch ® UltraMini ™ Meter uses one 3.0 Volt CR 2032 lithium battery (or equivalent). Replacement batteries can be found in most stores where batteries are sold. Your meter comes with the battery already installed. The meter shows a battery icon in the far right-hand side of the display to indicate the condition of the battery.
  • Page 41 If the meter does not power on after you have replaced the battery, check that the battery is correctly installed with the “+” side up. If the meter still does not power on, call LifeScan Customer Service at 1 800 227-8862.
  • Page 42: Understanding Error And Other Messages

    Understanding error and other messages The OneTouch ® UltraMini ™ Meter displays messages when there are problems with the test strip, with the meter, or when your blood glucose levels are higher than 600 mg/dL lower than 20 . Messages do not appear in all cases when a problem has occurred. mg/dL Improper use may cause an inaccurate result without producing a warning message.
  • Page 43 Message What it means What to do The meter has detected Repeat the test after the meter that the temperature is and test strips have reached a above the system temperature within the operating range. Do not operating range. perform a test until the meter and test strips reach a temperature within the operating...
  • Page 44 You can still perform a blood such as the first time use glucose test and get an accurate of the meter. test result. Contact LifeScan Customer Service at 1 800 227- Your meter was unable to 8862 to report this occurrence if recall this result.
  • Page 45 22–23. If the low end of the this error message appears system’s operating again, contact LifeScan Customer temperature range Service at 1 800 227-8862. (43–111 ° see top of next page...
  • Page 46 22–23. If this error moved during testing. message appears again, contact LifeScan Customer Service at 1 800 227-8862. The sample was If you applied the blood improperly applied.
  • Page 47 Message What it means What to do The meter has detected Repeat the test with a new a problem with the test test strip. Refer to pages 22–23 strip. Possible causes for information on sample are test strip damage or application.
  • Page 48: Detailed Information About Your System

    Detailed information about your system Comparing meter and laboratory results Test results with the OneTouch ® UltraMini ™ Meter are plasma-calibrated. This helps you and your healthcare professional to compare your meter results with laboratory tests. If you have been using another type of meter one that provides whole-blood-calibrated —...
  • Page 49 • Your hematocrit (percentage of blood that is red blood cells) is high (above 55%) or low (below 30%). • You are suffering from severe dehydration. • You tested at a temperature near the low end of the operating range (43°F) and you get a high glucose result (i.e., greater than 180 mg/dL).
  • Page 50 Technical specifications Reported result range 20–600 mg/dL Calibration Plasma-equivalent Sample Fresh capillary whole blood Sample size Minimum 1 microliter Test time 5 seconds Assay method Glucose oxidase biosensor Meter power source One replaceable 3.0 Volt CR 2032 lithium battery (or equivalent) Unit of measure mg/dL Memory...
  • Page 51 61000-4-2. This meter has been tested for immunity to radio frequency interference over the frequency range 80MHz to 2.5GHz at 3V/m as specified in IEC 61000-4-3. Degree of protection rating: IP32 Guarantee LifeScan guarantees that the OneTouch ® UltraMini ™...
  • Page 52: Index

    Index Alternate site testing procedure Fingertip testing procedure ......Battery 2, 35 Forearm 11, 17, 20, 22 .
  • Page 53 Low battery icon 35, 42 Test screen 3, 8 ............Low battery message 35, 42 Test strip, applying drop of blood...
  • Page 54 ® Test Strips. No test strip supplier other than LifeScan is authorized to grant such a license. The accuracy of results generated with LifeScan meters using test strips manufactured by anyone other than LifeScan has not been evaluated by LifeScan.
  • Page 55 24 horas al día, 7 días a la semana English 1 800 227-8862 Español 1 800 381-7226 Or/O bien, Visit us at/ Visitenos en: English www.LifeScan.com Español www.OneTouchEnEspanol.com © 2006 LifeScan, Inc. Milpitas, CA 95035 Rev. date: 04/2006 AW 06397301A...

This manual is also suitable for:

Ultramini - rev 4-2006

Table of Contents