Dimplex  26 Parts And Service Manual

Dimplex 26 Parts And Service Manual

26” outdoor electric fireplace
Hide thumbs Also See for DIMPLEX 26:

Advertisement

PARTS AND SERVICE MANUAL
FOR
DIMPLEX 26" OUTDOOR
ELECTRIC FIREPLACE
Model DFO2607

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex DIMPLEX 26

  • Page 1 PARTS AND SERVICE MANUAL DIMPLEX 26” OUTDOOR ELECTRIC FIREPLACE Model DFO2607...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS OPERATION PARTS DRAWING PARTS LIST WIRING DIAGRAM FRONT GLASS REMOVAL UPPER LIGHT REPLACEMENT LOWER LIGHT REPLACEMENT MAIN ON/OFF/FLAME CONTROL REPLACEMENT FLAME ROD AND MOTOR REPLACEMENT CIRCUIT BOARD REPLACEMENT AUDIO BOARD REPLACEMENT PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7...
  • Page 3: Operation

    DFO2607 OPERATION ELECTRIC FIREPLACE MANUAL CONTROL The manual controls for the firebox are located in the upper right hand corner behind the access panel. To access the controls, open the upper access panel by pulling forward and down. To locate controls refer to Figure 3. NOTE: The main on/off switch/flame action and flame brightness controls are always illuminated as long as the unit is plugged in.
  • Page 5: Parts List

    DFO2607 REPLACEMENT PARTS FIREBOX, 26” – Dimplex CATALOGUE NO. PART NO. REPLACEMENT PART 1. MOTOR, ASSEMBLY 2. LED LIGHT, TOP 3. SWITCHBOARD 4. CIRCUIT BOARD 5. MIRROR 6. GLASS FRONT 7. LED LIGHT, BOTTOM 8. TRANSFORMER 9. FLAME ROD 10. BUSHING 11.
  • Page 6: Wiring Diagram

    WIRING DIAGRAM...
  • Page 7: Front Glass Removal

    DFO2607 Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Lights need to be replaced when you notice a dark section of the flame. There are three lights under the log set which generate the flames and embers located under the emberbed.
  • Page 8: Upper Light Replacement

    DFO2607 Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Lights need to be replaced when you notice a dark section of the flame. There are three lights under the log set which generate the flames and embers located under the emberbed.
  • Page 9: Lower Light Replacement

    DFO2607 Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. Lights need to be replaced when you notice a dark section of the flame. There are three lights under the log set which generate the flames and embers located under the emberbed.
  • Page 10: Main On/Off/Flame Control Replacement

    DFO2607 Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons. MAIN ON/OFF SWITCH REPLACEMENT 1. Remove the front glass as shown on page 6 of this manual. 2. Remove the top trim piece by removing the 3 retaining screws. 3.
  • Page 11: Flame Rod And Motor Replacement

    DFO2607 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons.
  • Page 12: Circuit Board Replacement

    DFO2607 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons.
  • Page 13: Audio Board Replacement

    DFO2607 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin. Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons.

This manual is also suitable for:

Dfo2607

Table of Contents