Table 2
System-Level LEDs
Red CRIT LED
Red MAJ LED
Yellow MIN LED
Red REM LED
Green SYNC LED
Green ACO LED
TCC-I Card Specifications
•
•
•
•
•
78-14610-01
TCC-I System-Level Indicators
Definition
Used to indicate critical alarms in the network at the local terminal.
Used to indicate major alarms in the network at the local terminal.
Used to indicate a minor alarm in the network at the local terminal.
Provides first-level alarm isolation. The REM LED turns red when an alarm
is present in one or several of the remote terminals.
Used to indicate that node timing is synchronized to an external reference.
After pressing the alarm cutoff (ACO) button, the green ACO LED
illuminates. The ACO button opens the audible closure on the backplane.
ACO state is stopped if a new alarm occurs. After the originating alarm is
extinguished, the ACO LED and audible alarm control are reset.
CTC Software
Interface: 10 Base-T LAN (via back plane)
–
Access: on the MIC-A/P unit
–
Synchronization
Stratum 3 E, per ITU-T G.813
–
Free running access: accuracy + 4.6 ppm
–
Holdover Stability: 3.7 * 10
–
Reference: External BITS, line, internal
–
Environmental
Operating Temperature: -5 to +45 degrees Celsius
–
–
Operating Humidity: 5 - 95%, non-condensing
–
Power Consumption: 9.82 W, 0.20 A (AMPS) @ -48V, 33.5 BTU/Hr.
Dimensions
Height: 321.3 mm, (12.650 in.)
–
Width: 18.2 mm, (0.716 in.)
–
Depth: 228.6 mm, (9.000 in.)
–
Depth with backplane connector: 235 mm, (9.250 in.)
–
Weight not including clam shell: 0.7 kg (1.5 lbs.)
–
Compliance
ONS15454 SDH cards, when installed in a system, comply with these standards:
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260
–
TCC-I Timing Communication and Control Card Description
-7
/day including temperature (<255 slips in first 24 hours)
Installing ONS 15454 SDH TCC-I Cards
5