Oki CX1145 MFP Quick Installation page 6

Cx1145 mfp unpacking
Hide thumbs Also See for CX1145 MFP:

Advertisement

*59
*58
ADJUST
INSTALL
-1
The unit is
Installing toner cartridge
equipped with the auto setup function. Do
(STEP 59-2 to 59-13)
not turn the power OFF until the adjustment
When pressing the [HELP] button, the guidance
for steps *58 to *61 "Automatic Gamma
appears.
Adjustment for Printer PCL 600 dpi" is
completed.
. Install cartridges Y, M and C. For the installing
procedures, see steps 59-2 to 59-6.
Close the front cover after installing a
Initial Adjustment of the Auto-toner
cartridge and proceed to the next color by
. Turn the power switch ON.
pressing the button.
2. When the copier starts operating, the
2. Install the black cartridge after installing all
message "WAIT" appears.
color cartridges. For the installing procedures,
see steps 59-7 to 59-3.
3. Press the [FINISH] button.
WAIT
3. When adjustment has been performed, the
following message appears in a few minutes.
Upper: Current sensor voltage (V)
Middle: Adjustment value, Humidity (%)
Lower: Reference voltage for adjustment (V)
The current voltage (V) automatically changes
to come close gradually to the reference
voltage for the adjustment.
(In the order of K > C > M > Y)
Y: *****V M: *****V C: *****V K: 2.5V
Y: ***** M: ***** C: ***** K: ***** 39%
Y: *****V M: *****V C: *****V K: 2.5V
4. The change of the current voltage has been
stabilized the auto-toner output value (bit
value) is displayed in Middle, in a few minutes.
(In the order of K > C > M > Y)
Y: 1.25V M: 1.25V C: 1.25V K: 2.5V
Y: 73
M: 73
C: 75
K: 117
Y: 1.25V M: 1.25V C: 1.25V K: 2.5V
5. Press the [ENTER] button, then the
adjustment result is memorized and the
display returns to the initial screen.
100%
A
LT
TEST MODE
Note:
The equipment activates in the setup mode
automatically when the power is turned ON
before step *58 is finished normally.
*61
ADJUST
The following adjustment should be performed
Automatic Gamma Adjustment for
according to the order to be completed correctly.
Printer PS3 600 dpi
If "Readjust from IQC-Adjustment." or "Readjust
. Select the cassette of A4 (or LT) sized paper.
from Gamma-Adjustment (*)." appears on the
(If there is no A4 (or LT) sized paper in any
right side of the message "Adjustment step is not
cassette, be sure to set it.)
correct.", perform the adjustment again based
on the message.
2. [47] → [FAX]
Note: (*)
The test chart for the adjustment is output.
(): Automatic Gamma Adjustment for Copy
(2): Automatic Gamma Adjustment for Printer
100%
PS3 600 dpi
(3): Automatic Gamma Adjustment for Printer
PCL 600 dpi
3. Set the chart, facing down on the glass, in
order that 2 black solid rectangles be placed
Image Quality Control Adjustment
at the left side. Be sure to set the chart
1. [396] → [START]
aligned to the top left corner.
4. [1000] → [START]
100%
396
LT
The scanner automatically reads the original
TEST MODE
and carries out the calibration of gradation.
100%
2. When the copier starts operating, the
message "WAIT" appears.
TEST MODE
100%
396
LT
5. If the adjustment has failed in 4, "ERROR"
TEST MODE
WAIT
appears. The original might be deviating from
the appropriate setting position. Press the
[CANCEL] button, reset the original, return to
3. The adjustment operation will be completed in
3 and perform the operation again.
a few minutes and there will be a return to the
initial screen.
100%
100%
A
LT
TEST MODE
TEST MODE
6. Press the [ENTER] button.
Automatic Gamma Adjustment for Copy
Automatic Gamma Adjustment for
Printer PCL 600 dpi
. Select the cassette of A4 (or LT) sized paper.
(If there is no A4 (or LT) sized paper in any
. Select the cassette of A4 (or LT) sized paper.
cassette, be sure to set it.)
(If there is no A4 (or LT) sized paper in any
2. [4] → [FAX]
cassette, be sure to set it.)
The test chart for the adjustment is output.
2. [49] → [FAX]
The test chart for the adjustment is output.
4
100%
LT
100%
3. Set the chart, facing down on the glass, in
order that the 2 black solid rectangles be
3. Set the chart, facing down on the glass, in
placed at the left side. Be sure to set the chart
order that 2 black solid rectangles be placed
aligned to the top left corner.
at the left side. Be sure to set the chart
aligned to the top left corner.
4 [1642] → [START]
The scanner automatically reads the original
4. [1002] → [START]
and carries out the calibration of gradation.
The scanner automatically reads the original
and carries out the calibration of gradation.
100%
1642
LT
100%
TEST MODE
TEST MODE
5. If the adjustment has failed in 4, "ERROR"
appears. The original might be deviating from
the appropriate setting position. Press the
[CANCEL] button, reset the original, return to
3 and perform the operation again.
100%
1642
LT
TEST MODE
ERROR
6. Press the [ENTER] button.
5. If the adjustment has failed in 4, "ERROR"
appears. The original might be deviating from
the appropriate setting position. Press the
[CANCEL] button, reset the original, return to
3 and perform the operation again.
100%
1002
LT
TEST MODE
ERROR
47
LT
6. Press the [ENTER] button.
100%
1002
LT
TEST MODE
Adjustment completed
7. Press [CLEAR] button to return to the initial
screen.
100%
A
LT
TEST MODE
1000
LT
8. Press and hold [ENERGY SAVER] for a while
until the equipment is turned off.
1000
LT
ERROR
49
LT
1002
LT
6/
Setting the Date and Time
. Turn the power switch ON.
2. Press the [USER FUNCTIONS] button.
3. Press the [ADMIN] button, press the
[PASSWORD] button. Key in [123456] (Initial
value) of the [Admin Password] and then
press the [ENTER] button.
4. Press the [GENERAL], the [CLOCK] and the
[DATE/TIME] button.
5. Enter values for the year, month, date, hour
and minute, and press the [ENTER] button.