Installing Or Upgrading Identity Manager; Installing Business Continuity Clustering 1.1 - Novell BUSINESS CONTINUITY CLUSTERING 1.1 SP1 - 9-21-2010 ADMINISTRATION GUIDE FOR OPEN ENTERPRISE SERVER 1 SP2 LINUX Administration Manual

Table of Contents

Advertisement

In addition to upgrading NetWare, you must also apply the latest NetWare and Novell Cluster
Services patches to the upgraded servers. See the
Business Continuity Clustering 1.1 Readme file
(http://www.novell.com/documentation/bcc11/readme/data/readme11.html)
for instructions on the
necessary patches.
Performing a Rolling Cluster Upgrade
Performing a rolling upgrade to NetWare 6.5 SP5 (or SP6) and applying the latest patches lets you
keep your cluster up and running and lets your users continue to access the network while the
upgrade is being performed.
During a rolling cluster upgrade, one server is upgraded to NetWare 6.5 SP5 (or SP6) and the latest
patches are applied while the other servers in the cluster continue running a previous support pack of
NetWare 6.5. Then another server is upgraded to NetWare 6.5 SP5 (or SP6) with the latest patches,
and then another, until all servers in the cluster have been upgraded to NetWare 6.5 SP5 (or SP6)
with the latest patches.
After upgrading NetWare and applying the latest patches, reboot the server to automatically load
Cluster Services software.
During the upgrade process, cluster pools, volumes, and resources fail over from the server being
upgraded to other servers in the cluster. After a cluster server is upgraded and brought back online,
the pools, volumes, and resources that failed over to other servers during the upgrade process fail
back to the upgraded server.

3.1.2 Installing or Upgrading Identity Manager

You must upgrade to or install Identity Manager 2.x or 3 on one cluster server in each the Novell
Cluster Services clusters of your BCC. If you are upgrading to Identity Manager on a BCC server
®
where DirXML
is installed, see
"Upgrading" (http://www.novell.com/documentation/dirxml20/
admin/data/ampxjxi.html)
and
"Common Installation Scenarios" (http://www.novell.com/
documentation/dirxml20/admin/data/brpgxw9.html#brpgxw9)
in the Identity Manager 2.0.1
Administration Guide.
If you are installing Identity Manager, see
Section 2.1.6, "Identity Manager," on page
19.

3.1.3 Installing Business Continuity Clustering 1.1

After upgrading NetWare and Identity Manager, you must install Business Continuity Clustering 1.1
on all cluster nodes that will be part of your BCC. See
Section 2.2, "Installing Novell Business
Continuity Clustering Software," on page 21
for information on installing Business Continuity
Clustering 1.1.
The Business Continuity Clustering 1.1 installation program automatically detects if Business
Continuity Clustering 1.0 is installed and performs the necessary updates to convert 1.0 to 1.1. This
includes searching eDirectory
for SAN scripts and updating those scripts to be SMI-S compliant.
TM
60