OMNIFILTER
13845 Bishops Dr., Suite 200, Brookfield, WI 53005
Phone: 800.279.9404 • pentair .com
Tools and Fittings Required
For Installation with Copper Pipe:
• 2 Adjustable Wrenches or Pipe Wrenches
• Bushings if not installed on 1-inch pipe
• Pipe Cutter or Hacksaw
• Safety Glasses
• Pipe
• Plumber Tape
• Nipples
• File
• Unions
• Pencil
• Valves
Parts Included
• Housing wrench
• Mounting bracket
NOTES:
Galvanized fittings must be used with
galvanized pipe. Use Plumber Tape for
threaded connections
Optional Materials
Jumper Wire (See your Local Dealer)
For further operating, installation, maintenance,
parts or assistance:
Call Pentair Customer Service at
800.279.9404
Model WHH-10BB-VIH-SG-1
Heavy Duty Water Filtration System
INSTALLATION INSTRUCTIONS
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 2
Modelo WHH-10BB-VIH-SG-1
Sistema de filtración de agua pesada
INSTRUCCIONES DE INSTALACIÓN
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Página 7
Modèle WHH-10BB-VIH-SG-1
Système de filtration de l'eau lourde
INSTRUCTIONS D'INSTALLATION
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 11
Herramientas y coples requeridos
Para instalación con tubería de cobre:
• 2 llaves inglesas o llaves para tubería
• Cojinetes, si no se instala en una tubería de
1 pulgada
• Cortador de tubería o sierra para metales
• Gafas de seguridad
• Tubería
• Cinta de plomería
• Boquillas
• Lima
• Uniones
• Lápiz
• Válvulas
Piezas incluidas
• Llave para portafiltro
• Soporte de montaje
NOTAS:
Los accesorios galvanizados deben usarse
con la tubería galvanizada . Use la cinta de
plomería para las conexiones roscadas.
Materiales opcionales
Cable de puente (consulte a su representante
local)
Para mayor información sobre la operación,
instalación o el mantenimiento:
Llame al Servicio al Cliente de Pentair
800.279.9404
Outils et raccords necessaires
Pour installation avec tuyau de cuivre:
• 2 clés ajustables ou clés à tube
• Manchons s'ils ne sont pas installés sur le
tube de 1 pouce
• Coupe-tuyau ou scie à métaux
• Lunettes de
• Tuyau
sécurité
• Outil à emboîture
• Sparadrap
• Raccords
• Lime
• Valves
• Crayon
Pièces incluses
• Clé de boîtier
• Support de montage
REMARQUES:
Utilisez des raccords galvanisés avec un tuyau
galvanisé et du sparadrap pour les raccords
filetés.
Matériaux en option
Câble de raccordement temporaire (voir le
concessionnaire local)
Pour de tout autre renseignement concernant le
fonctionnement, l'installation ou l' e ntretien:
Appelez le service client Pentair en
composant le 800.279.9404

Advertisement

loading
Need help?

Need help?

Do you have a question about the OMNIFILTER WHH-10BB-VIH-SG-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair OMNIFILTER WHH-10BB-VIH-SG-1

  • Page 1 Pour de tout autre renseignement concernant le parts or assistance: instalación o el mantenimiento: fonctionnement, l’installation ou l’ e ntretien: Call Pentair Customer Service at Llame al Servicio al Cliente de Pentair Appelez le service client Pentair en 800.279.9404 800.279.9404 composant le 800.279.9404...
  • Page 2 . The weight of the filter should be supported so it does not stress the pipes. The main house water shut-off valve can be used as the inlet side shut-off valve . • 2 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 3 (or larger) around the filter (see Figure 5). The jumper wire must be connected at both ends by a pressure wire fitting or other connection that satisfies NEC or CEC and local codes. PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS• 3 •...
  • Page 4 2 . Turn on water supply. If leaks persist, or if there are other leaks on system, turn off water supply. Call Pentair Customer Service at: 800-279-9404. • 4 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 5 — 5 gpm 1 month Carbon WHC-10BB-I-5M-SG-2 *Nominal rating: Smaller micron rating equals finer filtration. Filter capacity is approximate and varies depending on conditions. ‡ PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 5 •...
  • Page 6 REPLACEMENT PARTS Part Number Description 154452 1-inch Valve-in-Head Cap WHO-HD-SG-6 tO-Ring 153114 Housing WHW-UNV-SG-6 Wrench WHB-HD-SG-3 Mounting Bracket • 6 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 7 Instalación sugirió los lados de la entrada y salida del filtro. La instalación que se muestra utiliza tubería de cobre. El peso del filtro debe PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 7 •...
  • Page 8 NEC o CEC . • 8 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 9 Si todavía hay pérdidas, o si hay otras pérdidas en el sistema, corte el suministro de agua. Llame al Servicio al Cliente de Pentair al 800-279-9404. PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 9 •...
  • Page 10 *Clasificación nominal: Una clasificación más pequeña en micrones significa una filtración más fina. La Filtro capacidad del cartucho el filtro es aproximada y varía según las condiciones. ‡ PIEZAS DE REPUESTO: página 15 • 10 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 11 Le filtre doit être supporté afin de ne pas peser sur les tuyaux. La valve principale d’arrêt d’ e au de la maison peut servir de valve d’arrêt d’arrivée. PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 11 •...
  • Page 12 à ses deux extrémités à un raccord pour câble à pression ou à une autre connexion conforme à NEC, CEC et aux codes locaux . • 12 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 13 Si la fuite persiste, ou s’il y a d’autres fuites dans l’appareil, coupez l’arrivée d’ e au. Appelez le service client Pentair en composant le 800-279-9404. PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 13 •...
  • Page 14 *Valeur nominal : Plus la valeur en micron est faible, plus le filtrage est fin. La filtre capacité de la cartouche est approximative, elle varie suivant les conditions d’utilisation. ‡ PIÈCES DE RECHANGE page 15 • 14 • PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 15 Store or seller’ s name/ Nombre de la tienda o del vendedor/Nom du magasin ou du vendeur Address/Dirección/Adresse City/Ciudad/Ville State/Estado/Province Zip/Código postal/Code postal Telephone/Teléfono/ Téléphone Seller’ s Signature/Firma del vendedor/Signature du vendeur Date/Fecha/Date Customer’ s Signature/Firma del cliente/Signature du client Date/Fecha/Date PENTAIR OMNIFILTER HEAVY DUTY WATER FILTRATION SYSTEM • INSTALLATION AND OPERATING INSTRUCTIONS • 15 •...
  • Page 16 P. 262.238.400 | CUSTOMER SERVICE: 800.279.9404 | tech-support@pentair.com | Pentair.com © 2023 Pentair. All rights reserved. All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered trademarks and logos are the property of their respective owners.

This manual is also suitable for:

Omnifilter whh-10-vih-sg-1Omnifilter whh-20bb-vih-sg-1