  • Page 1 Quick Start Guide Fronius Verto 15.0 Plus / 17.5 Plus 20.0 Plus / 25.0 Plus 30.0 Plus / 33.3 Plus manuals.fronius.com/ html/4204260552 OPERATING INSTRUCTIONS 42,0410,3021 005-05062025...
  • Page 2 This document does not describe all of the possible system configurations. Fronius International GmbH declares that the radio equipment type Fronius Verto Plus is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.fronius.com...
  • Page 3 Le soussigné, Fronius International GmbH, déclare que l’équipement radioélectrique du type Fronius Verto Plus est conforme à la directive 2014/53/UE. Le texte complet de la déclaration UE de conformité est disponible à l’adresse internet suivante: www.fronius.com...
  • Page 4 Pozor! PV-moduli, ki so izpostavljeni svetlobi, napajajo inverter z napetostjo. Ta dokument ne opisu- je vseh možnih konfiguracij sistema. Podjetje Fronius International GmbH s tem izjavlja, da je radijska oprema tipa Fronius Verto Plus v skladu z Direktivo 2014/53/EU.
  • Page 5: Mounting Conditions

    Warning signs explanation Tools General warning sign Electricity hazard Hot surface To note during installation Rating plate Safety information Mounting conditions 4001 m 90° 10° Mounting...
  • Page 6 Only one conductor may be connected to each pin (Except when using twin wire-end ferrules) 35 mm² 10 Nm 14 Nm 25 mm² 8 Nm 12 Nm 10 Nm 16 mm² 8 Nm 10 Nm 10 mm² 6 Nm 6 mm² 6 Nm 4 mm²...
  • Page 7: Control Panel

    Data communication (optional) Commissioning more information Control panel WLAN access point 3-6 sec. Quit Service Message Connected Standby Connecting (flashing) Uncritical Error (flashing) WPS active Network Error Critical Error Setup with mobile phone Rating plate www.fronius.com Fronius Solar.start open access point...
  • Page 8 DC min DC max Battery maximum input current (I BAT) 50 A DC max Fronius International GmbH Froniusstraße 1 4643 Pettenbach Austria contact@fronius.com www.fronius.com Under www.fronius.com/contact you will find the adresses of all Fronius Sales & Service Partners and locations.