Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 SAFETY INFORMATION Children shall not play with the appliance. This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
Page 3
Before disposing all refrigerant should be evacuated and disposed of as required by local environmental laws. • If there is any damage to the appliance, DO NOT USE and contact EIPL. • The appliance must not be used in a potentially explosive atmosphere.
Page 4
Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 GAS DETECTION Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) must not be used. The following leak detection methods are deemed acceptable for all refrigerant systems.
Page 6
Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 DEHUMIDIFIER PRINCIPLE Dehumidifiers remove moisture from the air that is circulating through the appliance. The resulting reduction of relative humidity helps prevent rust, rot, mould, mildew and condensation within the room, or other enclosed spaces where the dehumidifier is used.
Page 7
Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 INSTALLATION POSITIONING: Position the appliance in the centre of the room to be conditioned if at all possible. However, if a damp patch is particularly apparent the outlet grille should be pointed towards it.
Page 8
Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 RM40P CONTROL PANEL Button / Ledgend Function Description ON / OFF Switch the dehumidifier ON/OFF Cycle through menu options and adjust the Menu desired set point. See below for list of menu...
Page 9
Drawing : - TPC610 Issue : - 2 Date : - 03/07/25 MENU OPTIONS Pressing the Menu button cycles through the following pages of information. Menu Display Information Using the Up / Down Keys adjust the humidity to the desired Set RH set-point, pressing the Enter key to accept and save.
Page 10
Moving / Transporting the unit The RM40P has an inbuilt reservoir, which contains a small amount of water, therefore its’ advisable to allow any frost to melt, and empty this reservoir prior to moving.
Page 11
1. Insufficient air flow 1. Check all of the above Little or no water 2. Compressor fault 2. Contact EIPL extraction 3. Loss of refrigerant gas 3. Contact EIPL Little or no defrost 1. Faulty Timer 1.
Need help?
Do you have a question about the RM40P and is the answer not in the manual?