Download Print this page
EIPL EBAC PD200 Owner's Manual

EIPL EBAC PD200 Owner's Manual

Industrial dehumidifier

Advertisement

Quick Links

EBAC MODEL PD200
INDUSTRIAL DEHUMIDIFIER
OWNER'S MANUAL
www.eipl.co.uk
PD200 OWNERS MANUAL
Drawing No. :- TPC369
Issue
:- 5
Date
:- 24/11/16

Advertisement

loading
Need help?

Need help?

Do you have a question about the EBAC PD200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EIPL EBAC PD200

  • Page 1 Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.uk PD200 OWNERS MANUAL...
  • Page 2 Do not discard the packing, it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION The Ebac PD200 industrial dehumidifier removes moisture from the air through the refrigeration process. The Ebac PD200 is basically comprised of:...
  • Page 3: Specifications

    Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 SPECIFICATIONS M M M M : : : : Ebac PD200 ODEL ODEL ODEL ODEL H H H H : : : : 441mm EIGHT EIGHT EIGHT EIGHT 683mm W W W W...
  • Page 4: Installation

    Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it if possible.
  • Page 5 Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 OPERATION The following procedures should be followed to test the PD200 for correct operation: 1) After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Connect the power cable to a grounded power source. 2) Connect the drainage outlet to a suitably sized hose and run the hose to a permanent drain.
  • Page 6: Routine Service

    Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows:...
  • Page 7 Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault.
  • Page 8: Troubleshooting

    Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 TROUBLESHOOTING EMEDY YMPTOM AUSE 1. Check the power from the power Unit inoperative 1. no power to unit supply panel 1. Tighten fan 1. Loose fan on shaft 2. Replace the fan motor 2.
  • Page 9 Drawing No. :- TPC369 Issue :- 5 Date :- 24/11/16 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
  • Page 12 DL14 9AD Germany Tel: +44 (0) 1388 664400 Tel: +01 757 873 6800 Tel: +49 3043 557241 Fax: +44 (0) 1388 662590 Fax: +01 757 873 3632 Fax: +49 3043 557240 www.eipl.co.uk www.ebacusa.com www.eip-ltd.de sales@eipl.co.uk sales@ebacusa.com sales@eip-ltd.de PD200 OWNERS MANUAL...