EIPL RM40 Owner's Manual
Hide thumbs Also See for RM40:

Advertisement

Quick Links

INDUSTRIAL DEHUMIDIFIER
OWNER'S MANUAL
www.eipl.co.uk
RM40
Page 1 of 16
Drawing : - TPC470
Issue
: - 1
Date
: - 09/02/17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RM40 and is the answer not in the manual?

Questions and answers

Summary of Contents for EIPL RM40

  • Page 1 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 RM40 INDUSTRIAL DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.uk Page 1 of 16...
  • Page 2: Package Contents

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 RM40 PACKAGE CONTENTS Item Description Quantity 10187MG-US Dehumidifier 3086144 Quick release hose coupling 3944110 PVC Tube – 3/8” I/D 7.8M TPC470 Manual Page 2 of 16...
  • Page 3 Date : - 09/02/17 INTRODUCTION Designed for a wide range of applications, the RM40 is a rugged, industrial unit, which utilizes an energy-efficient compressor and a compact portable design to provide easy efficient drying. The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point.
  • Page 4: Specifications

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 SPECIFICATIONS : 10187MG-US ODEL : 24.2” (615 mm) EIGHT : 15” (382 mm) IDTH : 14.4” (365 mm) EPTH : 57lbs (26 kg) EIGHT : 88.3CFM (150 M /Hr) IRFLOW : 110V/ 60Hz/ 1 ph...
  • Page 5: Operation

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 OPERATION After unpacking, examine all external features to confirm damage-free shipment. Report all defects and damage at once. Before connecting it to the mains you should ensure that the humidistat is turned fully anti-clockwise.
  • Page 6 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 USE OF PERMANENT DRAINAGE When in use tubing should be run to a suitable drainage point, ensuring that the tube doesn’t rise above the drain tray, otherwise flooding may occur. CHECK DEHUMIDIFICATION PROCESS AS FOLLOWS: CAUTION: DO NOT REMOVE COVERS WHEN UNIT IS IN OPERATION...
  • Page 7: Routine Service

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 ROUTINE SERVICE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE SERVICE. THE SERVICING AND REPAIR OF THIS UNIT SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON.
  • Page 8 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 REPAIRS Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault.
  • Page 9: Troubleshooting

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 TROUBLESHOOTING YMPTOM AUSE EMEDY 1. Check the power from 1. No power to unit power supply panel. Unit inoperative 2. Mains cable damaged. 2. Contact the Factory Service Center 1.
  • Page 10: Spare Parts List

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 RM40 SPARE PARTS LIST ESCRIPTION UMBER UANTITY UMBER Timer 1617990 Condenser coil 2131147 Evaporator coil 1018611 Drain tray 2018705 Filter 1019712 Capillary 3014250 1.64ft Solenoid valve 3020836 Filter dryer...
  • Page 11 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 WARNINGS This appliance can be used by children from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the application in a safe way and understand the hazards involved.
  • Page 12: Limited Warranty

    Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
  • Page 13 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 Page 13 of 16...
  • Page 14 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 Page 14 of 16...
  • Page 15 Drawing : - TPC470 Issue : - 1 Date : - 09/02/17 Page 15 of 16...
  • Page 16 DL14 9AD Germany Tel: +44 (0) 1388 664400 Tel: +01 757 873 6800 Tel: +49 3043 557241 Fax: +44 (0) 1388 662590 Fax: +01 757 873 3632 Fax: +49 3043 557240 www.eipl.co.uk www.ebacusa.com www.eip-ltd.de sales@eipl.co.uk sales@ebacusa.com sales@eip-ltd.de Page 16 of 16...

This manual is also suitable for: