Page 1
Japan Phone +81 3 5309 2112 Phone +1 800.325.7425 Malaysia Vietnam Phone +603-8080 7425 Phone +65 6744 3732 Mexico Phone +52 (472) 748 9451 SICK AG, Erwin-Sick-Strasse 1, DE-79183 Waldkirch Detailed addresses and further locations at www.sick.com 2006/42/EC 2006/42/EC SAFETY...
Page 2
Input/Output Schematic 1 Brown: 12 ... 24 V DC 2 Load 3 Black: Control output 4 Main circuit 5 White: External input 1 12 ... 24 V DC 6 Protection circuit 2 External input 7 Blue: O V 3 O V 4 Control output...
Page 5
1 Open fiber lock lever. 2 Insert fiber into holes to stop. 3 Return fiber lock lever until it stops. 4 Fiber cable 5 Insertion sign of fiber cable Bus types WLL180T-M/L432 Base unit How to use fine fiber WLL180T-F/E232 Expansion unit Connection type...
Page 6
Expansion of base unit 1 Logic unit WI180C-B404 4 End unit 2 Base unit 5 Connector 3 Protection Cover...
Page 9
WLL180T-M/L432 WLL180T-M/L434 Base unit WLL180T-F/E232 WLL180T-F/E434 Expansion unit Connection type Cable M8 4-pin Control output NPN/PNP NPN/PNP open collector 100 mA/≤ 30 V DC resistive open collector 100 mA/≤ 30 V DC resistive Load current: ≤ 100 mA Load current: ≤ 100 mA Residual voltage ≤...
English English Safety Precautions Carefully read and understand the safety precautions before operation. The important information is provided to protect your health and property. Do not apply any other installing or operating procedure other than that described in these operating instructions. >...
Page 11
5. Initialization setting Reset all settings to the factory default. (Initial reset) (Initial reset) r S E t Select by using and fix by The screen returns to the top of initialization setting. Not initialize y E S Initialize 6. End of setting E n d Returns to the normal display.
Page 12
The base unit operates the Teach-in of all con- 4.8 Master Teach-in nected amplifier units. A t c h Select by using and fix by The screen returns to the top of master Teach-in setting. Does not perform Teach-in. y E S Performs all 1-point Teach-in.
Page 13
Options End unit BEF-EB01-W190 ‒ Specifications and equipment are subject to change without any obligations on the part of manufacture. ‒ For further information regarding configuration menue and Teach-in function please take note of the application manual or www.sick.com.
Page 14
1-Point Teach-in +10 % 1 Threshold Proximity variant: Through beam variant: Run teach-in on the background without Perform adjustment when there is an object. The switching threshold is set to 10% an object. above the received light value. 2-Point Teach-in 1 Threshold Proximity variant: step: set to an existing object..
Need help?
Do you have a question about the WLL180T and is the answer not in the manual?
Questions and answers