HP J4818A Installation And Getting Started Manual page 51

Procurve 2300 & 2500 series
Table of Contents

Advertisement

Tip
Problem

A transceiver
When you install transceivers in the transceiver slots, you must reset or reboot the switch
was installed and
so the switch processor can properly initialize and configure the transceiver. The flashing
the switch has
LED informs you that the transceiver is not initialized. The transceiver will not work
not yet been
properly until the switch is reset or rebooted.
reset.
ž
Errors are
When you press the Mode LED Select button to light the attention LED (labeled with a !),
occurring on the
the Mode LED for each port will flash briefly each time one of these packet types or
network
network events are detected on the port: jabber packet; packet with CRC error; oversized
packet; packet with alignment error; packet with symbol error; excessive collision
condition; late collision; inbound packet dropped.
If you see a large number of these events (the LED is flashing frequently, or is On
continuously), the possible causes are the following:
• bad quality or improperly wired cabling
• invalid topology -- usually a network of excessive length
• half/full-duplex mismatch -- For best operation, both the switch port and the connected
• improperly operating NIC or transceiver in the connected device
device should be configured to auto negotiate the link speed and connection mode
(full or half duplex). If a fixed configuration is required on the connected device, make
sure the switch port is configured to match both the speed AND the duplex setting of
the device. (Only Series 2500 switches can be configured -- Series 2300 switch ports
are set to auto negotiate the link parameters.)
Diagnosing with the LEDs
Solution
Troubleshooting
3-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procurve 2312Procurve 2324Procurve 2512Procurve 2524

Table of Contents