Port Type
Cable Type
62.5/125 µm or 50/125 µm core/cladding
100Base-FX
(on the 100-FX
diameter, graded-index, multimode fiber-optic
Transceiver)
cables that are fitted with SC connectors
62.5/125 µm or 50/125 µm core/cladding
Gigabit-SX
(on the
diameter, graded-index, multimode fiber-optic
Gigabit-SX
cables that are fitted with SC connectors
transceivers)
Gigabit-LX
Single-mode cables fitted with SC connectors.
(on the
62.5/125 µm or 50/125 µm core/cladding
Gigabit-LX
diameter, graded-index, multimode fiber-optic
transceivers)
cables may also be used, but a mode
conditioning patch cord may be needed — see
the Installation Guide that came with the
transceiver for more information.
I
Fiber Optic Cables
Installation Location - Before installing the switch, plan its location and
orientation relative to other devices and equipment:
In the front of the switch, leave at least 7.6 cm (3 inches) of space for
the twisted-pair and fiber-optic cabling.
In the back of the switch, leave at least 3.8 cm (1 1/2 inches) of space
for the power cord.
On the sides of the switch, leave at least 7.6 cm (3 inches) for cooling,
except if the switch is installed in an open EIA/TIA rack.
Installing the Series 2300 and 2500 Switches
Installation Procedures
Length Limits
• 2 kilometers for full-duplex connections
• 62.5 µm cable:
– 160 MHz*km = 220 meters
– 200 MHz*km = 275 meters
• 50 µm cable:
– 400 MHz*km = 500 meters
– 500 MHz*km = 550 meters
• single-mode cable - 5 kilometers
• multimode cable - 550 meters