• Maintain good ventilation around the display screen, controller, power supply and other devices, and keep a minimum 0.1 meter gap with other objects. • Do not stick or hang anything on the screen. CPS SERIES USER MANUAL - 3 -...
Page 4
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be requi red to correct the interference at his own expense CPS SERIES USER MANUAL - 4 -...
1 Product Introduction CPS series is specially developed high definition LED wall product for indoor commercial display market by Absen, featuring All-in-one minimalist design, completely cable-free integrated interior design, convenient installation and service. The product comes with both 320x480mm and 320x240mm sizes, especially suitable for the lobby, lecture hall, conference room, exhibition and other application scenarios.
﹣10~﹢40 Work temperature (℃) Storage humidity (RH) 10﹪~85﹪ Work humidity (RH) 10﹪~80﹪ IP rate(front/rear) IP40/IP21 Application parameter Lifetime(H) 100000 Maintenance Front Installation Front Note: Power consumption tolerance: ±15%, according to the actual situation. CPS SERIES USER MANUAL - 6 -...
2 Product components 2.1 Panel introduction Preserved for safety wire and plate Handle Module housing Data port Module Connecting kit Heat dissipation vent 3-in-1 system board Power port Rear cover Fixing screws CPS SERIES USER MANUAL - 9 -...
2.2 Product accessaris Looping cable (Data): Looping cable (Power): Main power cable:Cable length configured according to order requirements CPS SERIES USER MANUAL - 10 -...
Measure power Multipurpose cables and meter distribution boxes Laser level Measuring meter installation position Check the flatness of Spirit level ruler the box installation Measure the A tape measure dimensions of the steel structure CPS SERIES USER MANUAL - 11 -...
3. Construction of steel structure: according to the requirements of the drawings. Construction shall be combined with pipeline construction and supervised by the person in charge of installation. 4. Tools: Prepare tools commonly used for installing the display, such as screwdrivers, wrenches, and multimeters. CPS SERIES USER MANUAL - 12 -...
9. Display protection: In the process of installation and construction, dust collector should be used to reduce the dust concentration. After construction, clean canvas must be used to cover the large screen lamp surface to avoid dust and corrosive gas invading the lamp beads. CPS SERIES USER MANUAL - 13 -...
The meaning of 4*X+1*X in the table: 4 represents L+L+L+N wire, 1 represents PE wire, and X represents the size of the main cable. If the single-phase voltage is 110V, the international copper core cable type must be double; CPS SERIES USER MANUAL - 14 -...
1.Cable distribution ratio: Power cables and network cables are 1:1 by default. 2.When installing the box, handle it with care to avoid damage to the appearance and function of the module (lamp) caused by bump. Absen official QR code CPS SERIES USER MANUAL - 16 -...
Absen standard steel structure 4.2.2 Please reach out to our technical support for standard steel structure installation tutorial video. CPS SERIES USER MANUAL - 17 -...
5.2 Panel maintenance CPS series containers can be quickly removed using a vacuum adsorption tool for 3-5 seconds. Attach the front maintenance tool to the surface of the container to be removed, press a switch, and pull out the maintenance tool for 3-5 seconds.
Precautions 1. The CPS series maintenance tool can only use the Relor maintenance tool 2. The former maintenance tool should be placed in the middle area of a single box and cannot cross over to adjacent modules (if the specific location cannot be determined, you can enable Mapping to confirm the location).
4. Check the data cable of the receiving card; 5. Replace the data cable; 6. Send the rcfg file; 7. Upgrade the firmware version of the receiving card; 8. Replace the receiving card; CPS SERIES USER MANUAL - 20 -...
Page 21
AC input power supply (L / N / PE) and DC output terminal (VCC / GND). If there is a short circuit, please carefully investigate the wirings. Make sure all wirings are normal, and only then connect power to operate the unit. CPS SERIES USER MANUAL - 21 -...
Need help?